AJP - Heart Watch the video to see how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 279: H2720-H2725, 2000;
0363-6135/00 $5.00
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (20)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ringqvist, A.
Right arrow Articles by Wennmalm, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ringqvist, A.
Right arrow Articles by Wennmalm, A.
Vol. 279, Issue 6, H2720-H2725, December 2000

Diurnal variation of flow-mediated vasodilation in healthy premenopausal women

Åsa Ringqvist, Kenneth Caidahl, Ann-Sofi Petersson, and Åke Wennmalm

Department of Clinical Physiology, Göteborg University, Sahlgrenska University Hospital, SE 413 45 Göteborg, Sweden


    ABSTRACT
TOP
ABSTRACT
INTRODUCTION
SUBJECTS AND METHODS
RESULTS
DISCUSSION
REFERENCES

The present study was designed to test the hypothesis of a diurnal variation of endothelial function. Sixteen healthy, nonsmoking women were studied, each on four occasions during one 24-h period (2:00 PM, 8:00 PM, 2:00 AM, and 8:00 AM). Endothelial function was assessed by ultrasound determinations of flow-mediated vasodilation (FMD%) in the brachial artery. FMD% was contrasted with endothelium-independent vasodilation, i.e., nitroglycerine-induced vasodilation (NTG%). Additionally, plasma concentrations and urinary excretion of nitrate and cGMP were analyzed. FMD% and NTG% displayed diurnal, albeit not parallel, patterns of variation. Whereas FMD% gradually increased from 2:00 PM and peaked at 2:00 AM (means ± SE: 3.1 ± 0.4, 4.4 ± 0.4, 5.1 ± 0.9, and 3.9 ± 0.8%), the NTG% demonstrated a nadir at 2:00 AM. Plasma levels and urinary excretion of nitrate and cGMP did not display diurnal variation and no clear association with the variations seen in FMD% and NTG%. This study demonstrates a diurnal variation in both endothelium-dependent and -independent vasodilation in the brachial artery of healthy women. The background and possible implication of such a variation require further studies.

nitric oxide; nitrate; guanosine 3',5'-cyclic monophosphate; endothelium; catecholamines


    INTRODUCTION
TOP
ABSTRACT
INTRODUCTION
SUBJECTS AND METHODS
RESULTS
DISCUSSION
REFERENCES

THE INCIDENCE OF UNSTABLE ANGINA, myocardial infarction, stroke, sudden cardiac death, and pulmonary thromboembolism all display diurnal variation with an accumulation in the morning (20, 22). Proposed as underlying pathophysiological triggers of the increased cardiovascular vulnerability at this time of day have been morning hypercoagulability, hypofibrinolysis, and increased vascular tone (1, 3, 9, 23, 29). The diatomic molecule nitric oxide (NO), produced by endothelial cells, has been shown to induce relaxation of smooth muscle cells (21) and to inhibit platelet adhesiveness and aggregability (10, 24, 25). NO thus affects both vascular tone and platelet activity. Indeed, coronary segments with dysfunctional endothelium have been reported to display morning exaggeration in basal tone and in their constrictor response to acetylcholine, whereas segments with normally functioning endothelium showed no such variation (6). Hypothetically, this could imply that a healthy endothelium is involved in counteracting diurnal variations in vasoconstricting forces by altering its production of NO by time of day. The aim of this study was, consequently, to evaluate endothelial-derived NO production at different points of time during a 24-h period.

Direct measurements of NO production in vivo are complicated by the free radical properties and, consequently, rapid inactivation of the molecule. Therefore, indirect measurements of NO formation or activity have to be used. In this study, flow-mediated vasodilation (FMD%) and nitroglycerine-induced vasodilation (NTG%) of the brachial artery were determined by ultrasound. The assessment of FMD% was previously reported to adequately reflect NO-mediated vasodilation (13, 17). Additionally, analyses in plasma and urine of nitrate, the major metabolite of NO (34), and cGMP, the second messenger to NO, were performed. Sixteen healthy women were examined with these techniques, each on four occasions during a 24-h period (2:00 PM, 8:00 PM, 2:00 AM, and 8:00 AM), to test the hypothesis of a possible diurnal variation in endothelial function.


    SUBJECTS AND METHODS
TOP
ABSTRACT
INTRODUCTION
SUBJECTS AND METHODS
RESULTS
DISCUSSION
REFERENCES

Study Population

Sixteen healthy nonsmoking women aged 19-31 yr were studied. None of the participants were using any medication, including oral contraceptives. One study subject was excluded from statistical analyses of plasma and urinary excretion of nitrate. Her plasma level of nitrate was increased twofold on the second blood sampling occasion at 7:45 PM compared with the first occasion at 1:45 PM, followed by a gradual fall in concentrations on the third and fourth sampling occasions. From our experience (15), this indicates intake of nitrate-rich food, which was against the given instructions. Another study participant was excluded from statistical analyses of plasma norepinephrine due to hemolysis of one blood sample.

The participants were included in the study after verbal and written informed consent had been given. The study complied with the code of ethics of the Declaration of Helsinki and was approved by the local ethics committee.

Study Design

All participants were instructed to avoid strenuous exercise and to keep a nitrate/nitrite-poor diet during the 48 h preceding the study period and 24 h of each study occasion (14, 15). In addition, the subjects had to refrain from intake of caffeine-containing beverages during the study period.

The procedures took place in March 1997 in a temperature-controlled room (22-24°C). During four 24-h periods, the 16 study subjects were examined in groups of four. Because there were two investigators, the subjects were paired and examined by the same investigator throughout the 24-h period. The times of 2:00 PM, 8:00 PM, 2:00 AM, and 8:00 AM were selected as study points for the diurnal evaluation (a more detailed time schedule is given below). The study subjects could leave the hospital between the first and second examination but were otherwise inside the hospital. To not disturb the normal sleeping pattern, measures were taken to ensure a relaxed atmosphere. The study subjects slept for ~8 h, from 11:00-11.30 PM to 7:30 AM.

An intravenous cannula was inserted into an antecubital vein of the subject's left arm on arrival at the laboratory at 1:15 PM, i.e., 30 min before the first blood sample was collected. Blood was drawn from the intravenous cannula after at least 10 min of supine rest with 6-h intervals starting at 1:45 PM and ending at 7:45 AM. The first 5 ml of blood was discarded. After each blood sampling, the cannula was flushed with 10 ml of a solution of 0.3 ml 5,000 IU heparin/100 ml saline. Urine was collected in four portions; the first portion was collected between 7:30 AM and 1:30 PM, the second between 1:30 PM and 7:30 PM, the third between 7:30 AM and ~2:45 AM, i.e., after the third ultrasound examination was finished (in order not to alert the study subjects before the examination), and the fourth portion between ~2:45 AM and 7:30 AM. Ultrasound examinations were performed to determine FMD% and NTG%. These examinations were started at 2:00 PM, 8:00 PM, 2:00 AM, and 8:00 AM. The examinations of FMD% and NTG% lasted for ~40 min per study subject. The ultrasound examinations went on for 1 h 20 min after the points of time 2:00 PM, 8:00 PM, 2:00 AM, and 8:00 AM. One of the two study subjects (per investigator) was examined first on every one of the four study points. Blood pressure was controlled before the ultrasound examinations.

For clarity reasons, the points of time for biochemical and ultrasound analyses are presented as 2:00 PM, 8:00 PM, 2:00 AM, and 8:00 AM.

Flow-mediated vasodilation. B mode ultrasound images of the right brachial artery were obtained in longitudinal sections by use of identical 10.0-MHz linear phased array transducers and two Acuson 128 XP/10. After finding a satisfactory transducer position 6-10 cm proximal to the antecubital fossa, the transducer was fixed using a robot arm (Kanetec MB-FX) and kept in the same position throughout the examination. The skin was marked to ensure the same position on all four examinations. After a baseline scan had been recorded, arterial occlusion was elicited by a blood pressure cuff applied distally to the antecubital fossa and inflated to 250 mmHg for 4.5 min causing reactive hyperemia on its release (16). A second scan was recorded continuously from 30 s before to 90 s after cuff deflation. Doppler-derived blood flow measurements were recorded using a pulsed Doppler signal with angle correction in the center of the artery. Recordings of flow were performed at baseline and again during the first 15 s after cuff deflation.

Data evaluation. Brachial artery diameters were measured off-line by two observers from frozen images recorded on super-VHS videotape. Each investigator used three videotapes that were exchanged after each examination. The purpose was to scatter the investigations on the tapes to minimize the risk of bias on analysis. The computerized analyzing system and techniques of measurements have been described previously (33). Briefly, the system consists of a video tape player connected to a personal computer with an attached frame grabber and digitizer. Measurements were performed on four frozen images incident with the R wave of consecutive cardiac cycles on the electrocardiogram. The four measurements were later averaged. With the aid of the digitizer, a cursor was manually traced along 10 mm of the trailing edge of the near wall interface to the leading edge of the far wall interface. To assess flow-mediated diameter changes, measurements were made at baseline and 60 s after cuff deflation. Flow-mediated diameter (D) increase (FMD%) was defined as Delta D/Dbaseline × 100. The results of the two observers were averaged. Blood flow was calculated from the velocity time integral of the Doppler flow velocity and the calculated transverse vessel area and heart rate. Maximum blood flow was measured 10 s after the release of the blood pressure cuff.

Reproducibility. Reproducibility and variability of brachial artery measurements were calculated for the two observers and were as follows: baseline diameter: reproducibility, 3.43 ± 0.09 versus 3.40 ± 0.08 mm (r=0.96; P < 0.001); coefficient of variation (CV)% 2.91; maximal diameter during flow-dependent vasodilation: reproducibility, 3.57 ± 0.09 versus 3.56 ± 0.08 mm (r = 0.96; P < 0.001); CV% 2.86; percent change of brachial artery diameter during FMD%: reproducibility, 4.02 ± 0.64 versus 4.76 ± 0.74% (r = 0.84; P < 0.001); CV% 27.8.

NTG-induced vasodilation. Examination of NTG% was commenced 13 min after the release of the blood pressure cuff by recording a new baseline scan. Subsequently a 0.5-mg tablet of nitroglycerin was administered sublingually to the study subject. A new scan was recorded 3-4 min after nitroglycerin administration. The same analyzing procedure was made as described above.

Analysis of nitrate in blood and urine. Venous blood (5 ml) was drawn into heparin tubes. Plasma was separated by centrifugation at 3,000 rpm for 10 min and stored at -20°C until analysis. On analysis, a known volume of plasma/urine was added with a known amount of K15NO3 (Sigma, St. Louis, MO) as an internal standard. Subsequently, 50 µl of the plasma sample were added to an Eppendorf tube that had been kept at -80°C for 20 min containing a mixture of 750 µl of benzene and 120 µl of trifluoro-methane-sulphonic acid (TFMSA) (Sigma). (Upon urine analyses, the proportions were 20 µl of urine sample, 1,000 µl benzene, and 50 µl TFMSA.) The tube was shaken for 30 min, allowing endogenous and added nitrate to be converted to nitrobenzene. After centrifugation, 500-600 µl of the organic phase were separated and briefly washed with 150 µl of 0.5 M Na2CO3. Subsequently, 1 µl of the organic phase was injected into a temperature program (60-120°C)-controlled Varian 3400 gas chromatograph equipped with a 30-m XTI-5 capillary column. The gas chromatograph was connected to a Varian Saturn mass spectrometer operated in the positive ion/chemical ionization mode, selectively monitoring mass equivalent 124 for endogenous nitrate and mass equivalent 125 for the 15N-labeled internal standard. Methane was used as reactant gas. The detection limit for endogenous nitrate was 0.1 µM.

Analysis of cGMP in blood and urine. cGMP levels in plasma and urine were determined using a commercial 125I-labeled radioimmunoassay kit (RPA 525, Amersham International). Blood was collected in precooled EDTA tubes (7 ml) and kept on crushed ice. The tubes were immediately centrifuged for 10 min at 1,500 g (4°C), and plasma was removed. Plasma was diluted, and plasma proteins were precipitated by adding 1 ml of distilled water and 2 ml of triethylamine to 1 ml of plasma. After 20 s of shaking, the diluted plasma was centrifuged for 10 min at 1,500 g (4°C), and the supernatant was removed and stored at -70°C. Before analyses, the protein-depleted plasma was concentrated using SAX (Strong Anion Exchanger) columns (RPA 1918, Amersham International). The eluate was dried in a water bath (37°C) under a stream of nitrogen and afterward diluted with 1 ml of sodium azide buffer (assay buffer). On analysis, the solution was diluted 1:5 in assay buffer. cGMP in plasma was then determined according to the acetylation protocol.

Urine was diluted 1:40 in assay buffer and analyzed according to the nonacetylation protocol.

Analysis of epinephrine and norepinephrine in plasma. One to two milliliters of plasma was used for analysis. Catecholamines and other cis-diol metabolites were selectively isolated from plasma at pH 8.6 with the aid of acid-washed aluminiumoxide. Thereafter, the amines were eluted from the aluminiumoxide using a mixture of acetic acid and phosphorous acid. The sample was then analyzed with HPLC on a reverse-phase column. The catecholamines were selectively detected on an electrochemical detector within a cell with two porous graphite electrodes connected in series. The method is quantitative and is linear in the interval of 0.1-400 pmol (7).

Analysis of lipids and lipoproteins in serum. Cholesterol and triglyceride levels were determined by fully enzymatic techniques by using a Gilford System 3500 Autoanalyser (Gilford Instruments, Oberlin, OH). High-density lipoprotein cholesterol (HDL-C) was determined after precipitation of apolipoprotein B-containing lipoproteins with manganese chloride and heparin. Low-density lipoprotein cholesterol (LDL-C) was calculated according to Friedewald et al. (8).

Statistical Methods

One-way ANOVA was used to determine the effect of time of day. When an overall effect of time was found, subsequent contrast analysis was performed. Linear regression analysis (Pearsson) was performed to evaluate reproducibility. When CV% for FMD% was calculated, SD was determined using the formula SD = [Sigma (x1 - x2)2/2N]1/2 (2). P < 0.05 was regarded as statistically significant. Background tabulated data are presented as means ± SD to illustrate the variability in the sample, whereas main study variables in the figures are presented as means ± SE to quantify the uncertainty in the estimate of the true mean.


    RESULTS
TOP
ABSTRACT
INTRODUCTION
SUBJECTS AND METHODS
RESULTS
DISCUSSION
REFERENCES

The procedures were well tolerated by the participants. At 2:00 AM, the majority of the study subjects were asleep or in a slumber during the blood sample collection and ultrasound examinations.

Systolic blood pressure varied significantly during the 24 h (P < 0.01), displaying a marked nadir at 2:00 AM (P < 0.001) and subsequent increase in the morning (P < 0.01). Diastolic blood pressure and heart rate did not show any diurnal variation (Table 1). Serum cortisol concentrations varied significantly with the characteristic morning increase (P < 0.001) and displayed a significant difference (P < 0.001) between each time point except between 8:00 PM and 2:00 AM (Table 1). A diurnal pattern was detected in plasma norepinephrine (P < 0.001), with higher concentrations at 2:00 PM and 8:00 PM and lower concentrations at 2:00 AM and 8:00 AM (P < 0.001). Plasma epinephrine did not display any variation over the 24 h (Table 1). Diurnal variations were noted in the levels of serum lipids and lipoproteins. Thus total cholesterol, LDL-C, and HDL-C concentrations were significantly lower at 2:00 AM compared with daytime values (P < 0.05 to P < 0.001), with the exception that total cholesterol did not differ between 2:00 AM and 8:00 AM. An opposite pattern was noted for serum triglycerides, the concentrations of which were higher (P < 0.01) at 2:00 AM (as well as at 8:00 PM) compared with 2:00 PM and 8:00 AM. Although mean values for FMD% varied in the same direction as serum triglyceride levels and opposite the HDL-C levels, there was no significant correlation between change in FMD% and change in serum lipid or lipoprotein levels.

                              
View this table:
[in this window]
[in a new window]
 
Table 1.   Blood pressure, HR, serum cortisol, plasma catecholamines, serum lipids, and lipoproteins measured with 6-h intervals during one 24-h period

FMD% displayed a diurnal variation (means ± SE: 3.1 ± 0.4, 4.4 ± 0.4, 5.1 ± 0.9, and 3.9 ± 0.8%; P < 0.05) and increased gradually from 2:00 PM to 2:00 AM (P < 0.01). NTG% also demonstrated diurnal variation (P < 0.05) with a biphasic pattern, i.e., a weak tendency to increase 2:00 PM-8:00 PM (P = 0.09), a tendency to decrease 8:00 PM-2:00 AM (P = 0.07), and a significant increase 2:00 AM-8:00 AM (P < 0.05). At 2:00 PM, NTG% was significantly lower than at 8:00 AM (P < 0.05) (Fig. 1A). A significant (P < 0.001) variation was detected in basal vessel diameter with a larger diameter at 2:00 AM compared with 8:00 PM (P < 0.01) and 8:00 AM (P < 0.001) (Fig. 1B). Blood flow increase in response to hyperemia did not display any diurnal variation (mean 516 ± 35 ml/min), whereas shear rate increase (shear rate was calculated using the basal diameter and volume flow) did (P < 0.01). The diurnal patterns of shear rate increase and FMD% were, however, not parallel (Fig. 1B).


View larger version (17K):
[in this window]
[in a new window]
 
Fig. 1.   Ultrasonographic examinations in the brachial artery at 4 points of time during 1 24-h period. Percentage increase of the brachial artery diameter 1 min after the release of a 4.5 min distal arterial occlusion (FMD%) and nitroglycerin-induced vasodilation (NTG%) (A). Brachial artery diameter in the basal state and shear rate increase 10 s after release of the blood pressure cuff compared with at basal (B). A circadian rhythm was detected in FMD% (P < 0.05) with a gradual increase from 2:00 PM to 2:00 AM. NTG% showed a somewhat different pattern with a nadir at 2:00 AM (P < 0.05). The brachial artery diameter in the basal state varied (P < 0.001), with the largest diameter at 2:00 AM. Determination of shear rate increase was performed for every examination to rule out the possibility of a circadian rhythm that could explain the circadian pattern of FMD%. Shear rate increase did in fact display circadian variation (P < 0.01), however, not parallel to the FMD% variation. *P < 0.05; **P < 0.01; ***P < 0.001.

Neither plasma concentrations of nitrate and cGMP (Fig. 2A) nor urinary excretion of nitrate or cGMP displayed any significant diurnal variation (Fig. 2B). However, the difference in the rate of urinary cGMP excretion measured at 2:00 AM compared with that at 2:00 PM correlated to the difference in FMD% between these time points (r = 0.76, P = 0.003).


View larger version (17K):
[in this window]
[in a new window]
 
Fig. 2.   Plasma concentrations of nitrate and cGMP on 4 occasions during 1 24-h period (A). Urine collection in 4 portions during the 24 h for analyses of nitrate and cGMP excretion (B). No significant diurnal variation was found in either plasma concentrations or urinary excretion of nitrate and cGMP.


    DISCUSSION
TOP
ABSTRACT
INTRODUCTION
SUBJECTS AND METHODS
RESULTS
DISCUSSION
REFERENCES

The major new finding in the present study was the diurnal variation of FMD%. FMD% was previously shown to adequately reflect release of endothelial-derived NO in response to flow (13, 18). This would seemingly imply a diurnal variation in NO production in response to flow, with its greatest capacity at night. However, the analyses of NTG%, nitrate, and cGMP did not support such a concept.

It was considered important for the outcome of the study that the subjects did display a normal diurnal rhythm. Serum levels of cortisol, displaying a marked elevation in the morning, have a diurnal variation that is well established (32). Serum cortisol was, therefore, measured and was found to display a distinct diurnal variation in all the study subjects. Because the study subjects also reported to have slept well during the night of the study, we assume that the study conditions did not substantially disturb the normal diurnal rhythm.

FMD% has been shown to be related to HDL cholesterol (26, 30), but we did not find any significant relation between change in FMD% and diurnal change in lipids or lipoproteins.

Reproducibility for brachial artery inner diameter measurements is excellent, with a CV% around 3% in our study and in that by Hata et al. (11). Previous methodological studies indicated the possibility to detect within-subject changes in FMD% in the order of 2% provided a sample size similar to the current investigation (27). Not only endothelium-dependent (i.e., FMD%), but also endothelium-independent, i.e., NTG-induced, vasodilation (NTG%) were found to display diurnal variation. However, the pattern of NTG% differed from the diurnal pattern of FMD%; instead of displaying a maximum between 2:00 and 3:00 AM, NTG% was low at this point of time. This indicates that smooth muscle diurnal variation in sensitivity to NTG, and thus to NO, is not sufficient to explain the diurnal variation in FMD%.

NO production has several links to sympathetic vasoconstrictor activity. Thus the endothelium has been reported to inhibit the release of norepinephrine from sympathetic nerve terminals and also to increase norepinephrine metabolism in the rabbit carotid artery (5). Furthermore, the molecule is considered to counteract adrenergic vasoconstriction (4, 28). It has even been proposed that an important mechanism of vasodilation by NO is inhibition of peripheral sympathetic vasoconstriction (35). An increase in sympathetic tone has also been proposed to enhance vascular NO release by inducing increased shear stress and by direct agonistic stimulation (12, 31). These data suggest that NO, in several respects, acts as a feedback inhibitor of sympathetic vasoconstrictor activity.

Diurnal variations of vascular tone, alpha -sympathetic vasoconstrictor activity, and catecholamines have previously been reported, with increases of all these variables in the morning (19, 23). In this study, systolic blood pressure and basal vessel diameter displayed a diurnal variation, with lower systolic blood pressure and a larger vessel diameter at night. At the same time, plasma norepinephrine concentrations fell markedly. Taken together, this confirms that the sympathetic activity of the study subjects was lower at night (2:00-3:00 AM). Hence, one or several of the above-mentioned mechanisms implying a NO-induced feedback inhibition of sympathetic vasoconstriction was probably not responsible for the increased FMD% at 2:00-3:00 AM presently observed. Rather, one may speculate that FMD% might have increased at night as a result of the concurrent attenuated sympathetic activity. It is possible that the increased formation of endothelial NO in response to flow might cause greater relaxation of the smooth muscle cells when less counteracted by perivascular sympathetic nerves. However, the fact that the brachial artery responded less to nitroglycerin at 2:00-3:00 AM speaks against an increased responsiveness of the smooth muscle cells to NO at night. Thus it is less likely that the increased FMD% at night (2:00-3:00 AM) was due only to decreased sympathetic activity.

One alternative explanation for the diurnal pattern of FMD% might have been a difference in shear forces acting on the vessel wall at different times of day with elevated shear stress increases when FMD% was higher and vice versa. However, neither blood flow increases nor shear rate increases in response to hyperemia displayed a pattern that could explain the diurnal rhythm of FMD%.

Biochemical assessment of NO production at the four points of time was reflected by determinations of nitrate and cGMP in plasma and urine. A diurnal variation could not be detected in these variables. Thus the concept that the observed diurnal pattern of FMD% reflected a diurnal variation in NO production was not supported despite the fact that we have found a low variability of nitrate levels in subjects on a nitrate/nitrite-poor diet (15).

Our study gives no clear-cut evidence for a variation of NO production by time of day. Yet, the different rhythms of FMD% and NTG% over the 24 h might imply such a variation. The question whether NO-production displays diurnal variation can only be answered by further studies, possibly by administration of NO synthase blockers to investigate whether this abolishes the diurnal variation of FMD%.


    ACKNOWLEDGEMENTS

The authors are grateful to Prof. John Wikstrand and Inger Wendelhag, Ph.D., Göteborg University, Sweden, as well as to Acuson, Sweden, for generously supplying us with ultrasound equipment and technical help during analyses of the ultrasound investigations.


    FOOTNOTES

This study was supported by grants from the Swedish Medical Research Council (K99-04RM-13192-01), the Swedish Heart Lung Foundation, and from "Förenade Liv" Mutual Group Life Insurance, Stockholm, Sweden, as well as from the Göteborg Medical Society, Göteborg, Sweden.

Address for reprint requests and other correspondence: K. Caidahl, Dept. of Clinical Physiology, Göteborg Univ., Sahlgrenska Univ. Hospital, S-413 45 Göteborg, Sweden (E-mail: caidahl{at}.clinphys.gu.se).

The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.

Received 11 March 1999; accepted in final form 28 June 2000.


    REFERENCES
TOP
ABSTRACT
INTRODUCTION
SUBJECTS AND METHODS
RESULTS
DISCUSSION
REFERENCES

1.   Andreotti, F, Davies GJ, Hackett DR, Khan MI, De Bart ACW, Aber VR, Maseri A, and Kluft C. Major diurnal fluctuations in fibrinolytic factors and possible relevance to time of onset of myocardial infarction, sudden death and stroke. Am J Cardiol 62: 635-637, 1988[ISI][Medline].

2.   Bland, M. An Introduction to Medical Statistics. Oxford, UK: Oxford Medical Publications, 1987, p. 276-278.

3.   Chandler, WL. A kinetic model of the circulatory regulation of tissue plasminogen activator. Thromb Haemost 66: 321-322, 1991[ISI][Medline].

4.   Cocks, TM, and Angus JA. Endothelium-dependent relaxation of coronary arteries by noradrenaline and serotonin. Nature 305: 627-629, 1983[Medline].

5.   Cohen, RA, and Weisbrod RM. Endothelium inhibits norepinephrine release from adrenergic nerves of rabbit carotid artery. Am J Physiol Heart Circ Physiol 254: H871-H878, 1988[Abstract/Free Full Text].

6.   El-Tamimi, H, Mansour M, Pepine CJ, Wargovich TJ, and Chen H. Diurnal variation in coronary tones in patients with stable angina. Protective role of the endothelium. Circulation 92: 3201-3205, 1995[Abstract/Free Full Text].

7.   Eriksson, BM, and Persson BA. Determination of cathecholamines in rat heart tissue and plasma by liquid chromatography with electrochemical detection. J Chromatogr A 228: 143-154, 1982.

8.   Friedewald, WT, Levy RI, and Fredrickson DS. Estimation of the concentration of low-density lipoprotein cholesterol in plasma, without use of the preparative ultracentrifuge. Clin Chem 18: 499-502, 1972[Abstract].

9.   Fujita, M, and Franklin D. Diurnal changes in coronary blood flow in conscious dogs. Circulation 76: 488-491, 1987[Abstract/Free Full Text].

10.   Furlong, B, Hendersson AH, Lewis MJ, and Smith JA. Endothelium-derived relaxing factor inhibits in vitro platelet aggregation. Br J Pharmacol 90: 687-692, 1987[ISI][Medline].

11.   Hata, A, Reid CL, Ogata T, Tokushima T, and Gardin JM. Reproducibility of brachial artery ultrasound measurements. Echocardiography 16: 367-372, 1999[ISI][Medline].

12.   Hu, ZW, Miller JW, and Hoffman BB. Induction of enhanced release of endothelium-derived relaxing factor after prolonged exposure to alpha -adrenergic agonists: role in desensitization of smooth muscle contraction. J Cardiovasc Pharmacol 23: 337-343, 1994[ISI][Medline].

13.   Joannides, R, Haefeli WE, Linder L, Richard V, Bakkali EH, Thuillez C, and Luscher TF. Nitric oxide is responsible for flow-dependent dilatation of human peripheral conduit arteries in vivo. Circulation 91: 1314-1319, 1995[Abstract/Free Full Text].

14.   Jungersten, L, Ambring A, Wall B, and Wennmalm Å. Both physical fitness and acute exercise regulate nitric oxide formation in healthy humans. J Appl Physiol 82: 760-764, 1997[Abstract/Free Full Text].

15.   Jungersten, L, Edlund A, Petersson AS, and Wennmalm Å. Plasma nitrate as an index of nitric oxide formation in man: Analyses of kinetics and confounding factors. Clin Physiol 16: 369-379, 1996[ISI][Medline].

16.   Leeson, P, Thorne S, Donald A, Mullen M, Clarkson P, and Deanfield J. Non-invasive measurement of endothelial function: effect on brachial artery dilatation of graded endothelial dependent and independent stimuli. Heart 78: 22-27, 1997[Abstract/Free Full Text].

17.   Lieberman, E, Knab S, and Creager M. Nitric oxide mediates the vasodilator responses to flow in human (Abstract). Circulation 90: I-138, 1994.

18.   Lieberman, EH, Gerhard MD, Uehata A, Selwyn AP, Ganz P, Yeung AC, and Creager MA. Flow-induced vasodilation of the human brachial artery is impaired in patients <40 years of age with coronary artery disease. Am J Cardiol 78: 1210-1214, 1996[ISI][Medline].

19.   Linsell, CR, Ligthman SL, Mullen PE, Brown MJ, and Causon RC. Diurnal rhythms of epinephrine and norepinephrine in man. J Clin Endocrinol Metab 60: 1210-1215, 1985[Abstract].

20.   Manfredini, R, Gallerani M, Portaluppi F, and Fersini C. Relationships of the diurnal rhytms of thrombitic, ischemic, hemorrhagic, and arrhythmic events to blood pressure rhytms. Ann NY Acad Sci 783: 141-158, 1996[Medline].

21.   Moncada, S, Palmer RMJ, and Higgs EA. Nitric oxide: physiology, pathophysiology, and pharmacology. Pharmacol Rev 43: 109-142, 1991[ISI][Medline].

22.   Muller, JE, Tofler GH, and Stone PH. Diurnal variation and triggers of onset of acute cardiovascular disease. Circulation 79: 733-743, 1989[Abstract/Free Full Text].

23.   Panza, JA, Epstein SE, and Quyyumi AA. Diurnal variation in vascular tone and its relation to alpha -sympathetic vasoconstrictor activity. N Engl J Med 325: 986-990, 1991[Abstract].

24.   Radomski, MW, Palmer RMJ, and Moncada S. The role of nitric oxide and cGMP in platelet adhesion to vascular endothelium. Biochem Biophys Res Commun 148: 1482-1489, 1987[ISI][Medline].

25.   Radomski, MW, Rees DD, Dutra A, and Moncada S. S-nitroso-gluthatione inhibits platelet activation in vitro and in vivo. Br J Pharmacol 107: 745-749, 1992[ISI][Medline].

26.   Simons, LA, Sullivan D, Simons J, and Celermajer DS. Effects of atorvastatin monotherapy and simvastatin plus cholestyramine on arterial endothelial function in patients with severe primary hypercholesterolaemia. Atherosclerosis 137: 197-203, 1998[ISI][Medline].

27.   Sorensen, KE, Celermajer DS, Spiegelhalter DJ, Georgakopoulos D, Robinson J, Thomas O, and Deanfield JE. Non-invasive measurement of human endothelium dependent arterial responses: accuracy and reproducibility. Br Heart J 74: 247-253, 1995[Abstract/Free Full Text].

28.   Tesfamariam, B, and Cohen RA. Inhibition of adrenergic vasoconstriction by endothelial cell shear. Circ Res 63: 720-725, 1988[Abstract/Free Full Text].

29.   Tofler, GH, Brezinski D, Schafer AI, Czeisler CA, Rutherford JD, Willich SN, Gleason RE, Williams GH, and Muller JE. Concurrent morning increase in platelet aggregability and the risk of myocardial infarction and sudden cardiac death. N Engl J Med 316: 1514-1518, 1987[Abstract].

30.   Toikka, JO, Ahotupa M, Viikari JSA, Niinikoski H, Taskinen MR, Irjala K, Hartiala JJ, and Raitakari OT. Constantly low HDL-cholesterol concentration relates to endothelial dysfunction and increased in vivo LDL-oxidation in healthy young men. Atherosclerosis 147: 133-138, 1999[ISI][Medline].

31.   Vanhoutte, PM, Rubanyi GM, Miller VM, and Houston DS. Modulation of vascular smooth muscle contraction by the endothelium. Annu Rev Physiol 48: 307-320, 1986[ISI][Medline].

32.   Weitzman, ED, Fukushima D, Nogeire C, Roffwary H, Gallagher TF, and Hellman L. Twenty-four hour pattern of the episodic secretion of cortisol in normal subjects. J Clin Endocrinol Metab 33: 14-22, 1971[ISI][Medline].

33.   Wendelhag, I, Gustavsson T, Suurküla M, Berglund G, and Wikstrand J. Ultrasound measurement of wall thickness in the carotid artery: fundamental principles and description of a computerized analysing system. Clin Physiol 11: 565-577, 1991[ISI][Medline].

34.   Wennmalm, Å, Benthin G, Edlund A, Jungersten L, Kieler-Jensen N, Lundin S, Nathorst-Westfelt U, Petersson AS, and Waagstein F. Metabolism and excretion of nitric oxide in humans. An experimental and clinical study. Circ Res 73: 1121-1127, 1993[Abstract/Free Full Text].

35.   Zanzinger, J, Czachurski J, and Seller H. Inhibition of sympathetic vasoconstriction is a major principle of vasodilation by nitric oxide in vivo. Circ Res 75: 1073-1077, 1994[Abstract/Free Full Text].


Am J Physiol Heart Circ Physiol 279(6):H2720-H2725
0363-6135/00 $5.00 Copyright © 2000 the American Physiological Society



This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. A. Wauschkuhn, K. Witte, S. Gorbey, B. Lemmer, and L. Schilling
Circadian periodicity of cerebral blood flow revealed by laser-Doppler flowmetry in awake rats: relation to blood pressure and activity
Am J Physiol Heart Circ Physiol, October 1, 2005; 289(4): H1662 - H1668.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. J.M. Broadley, A. Korszun, E. Abdelaal, V. Moskvina, C. J.H. Jones, G. B. Nash, C. Ray, J. Deanfield, and M. P. Frenneaux
Inhibition of Cortisol Production With Metyrapone Prevents Mental Stress-Induced Endothelial Dysfunction and Baroreflex Impairment
J. Am. Coll. Cardiol., July 19, 2005; 46(2): 344 - 350.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
M. L. Bots, J. Westerink, T. J. Rabelink, and E. J.P. de Koning
Assessment of flow-mediated vasodilatation (FMD) of the brachial artery: effects of technical aspects of the FMD measurement on the FMD response
Eur. Heart J., February 2, 2005; 26(4): 363 - 368.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
S. Xiang, R. Denver, M. Bailey, and H. Krum
Physiologic Determinants of Endothelin Concentrations in Human Saliva
Clin. Chem., December 1, 2003; 49(12): 2012 - 2019.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. L. Hijmering, E. S. G. Stroes, J. Olijhoek, B. A. Hutten, P. J. Blankestijn, and T. J. Rabelink
Sympathetic activation markedly reduces endothelium-dependent, flow-mediated vasodilation
J. Am. Coll. Cardiol., February 20, 2002; 39(4): 683 - 688.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (20)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ringqvist, A.
Right arrow Articles by Wennmalm, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ringqvist, A.
Right arrow Articles by Wennmalm, A.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online