Division of Cardiology, University of Utah Health Sciences Center, Salt Lake City, Utah 84132
| |
ABSTRACT |
|---|
|
|
|---|
We examined the dependence of peak Na+ pump and Na+/Ca2+ exchanger currents on prior Na+ pump inhibition induced by exposure to zero extracellular K+ in voltage-clamped adult murine ventricular myocytes. Abrupt activation of the Na+ pump by reexposure of myocytes to extracellular K+ with a rapid solution switcher resulted in the development of a transient peak current at ~500 ms, followed by a decline over 1-2 min to a steady-state level. The magnitudes of both the peak Na+ pump current (Ip) and the peak outward Na+/Ca2+ exchange current, activated by rapidly reducing extracellular Na+ to zero with the solution switcher, were dependent on previous Na+ pump activity. [Na+] gradients (Na+-binding benzofuran isophthalate fluorescence) between the patch pipette and the bulk cytosol were relatively small and could not account for the large differences between peak and steady-state Ip and reverse Na+/Ca2+ exchanger currents. Our results are consistent with the presence of a subsarcolemmal Na+ concentration gradient, which is similar for the Na+ pump and the Na+/Ca2+ exchanger. These findings also support the hypothesis that the Na+ pump and the Na+/Ca2+ exchanger are colocalized in the sarcolemma.
sodium pump current; sarcolemma; calcium
| |
INTRODUCTION |
|---|
|
|
|---|
THE SARCOLEMMAL Na+-K+-ATPase, the "Na+ pump," utilizes energy derived from the hydrolysis of ATP to extrude three Na+ in exchange for two K+ (31). The Na+ pump thus generates an outward current that can be quantified by voltage-clamp techniques. In vitro studies of isolated canine cardiac sarcolemmal vesicles (25) and of partially purified cardiac Na+-K+-ATPase (1) have demonstrated a marked sensitivity to Na+ concentration at the internal surface of the transport enzyme with a dissociation constant (Kd) for activation of the Na+-K+-ATPase by Na+ of 10-20 mM. As pointed out by Semb and Sejersted (28), some studies in intact voltage-clamped guinea pig ventricular myocytes in which the intracellular Na+ concentration ([Na+]i) has been varied by changing the concentration of Na+ in the patch pipette have shown a considerably lower apparent sensitivity of the steady-state Na+ pump current (Ip) to [Na+]i (see Refs. 21 and 30). Although a theoretical analysis suggests that the steady-state cytosolic [Na+] is determined by the pipette [Na+] (21), this discrepancy could be due to a failure of the pipette [Na+] to adequately control the subsarcolemmal [Na+]. Indeed, Bielen et al. (4) have shown that in voltage-clamped ventricular myocytes when the Na+ pump is inhibited by exposure to zero extracellular K+ (K+o) and then abruptly reactivated by a resupply of K+o, a transient peak in Ip can be observed, which then decays over 1-2 min to a steady-state level. This transient increase in Na+ pump activity has been interpreted as possibly reflecting the presence of a [Na+] gradient between the bulk cytosol, where the [Na+] is controlled by the patch pipette, and a subsarcolemmal space, the so-called Na+ "fuzzy space" (14), where the abrupt activation of the Na+ pump could cause local depletion of intracellular Na+ with a resulting fall in the [Na+] to a level considerably below that present in the patch pipette (5). However, other factors could cause this type of behavior of Ip on abrupt reactivation of the Na+ pump, including the development of a substantial gradient in [Na+] between the pipette and the bulk cytosol due to limited diffusion of Na+ from the tip of the patch pipette and depletion of K+o at the extracellular pump site due to either diffusion limitations in T tubules or adjacent to the K+ binding site on the Na+ pump (24).
We have recently demonstrated that isolated mouse adult ventricular myocytes have a high resting [Na+]i (15-16 mM; Ref. 33). This relatively high resting [Na+]i permits examination of Ip at a pipette [Na+] equal to and below the resting [Na+]i, conditions in which a gradient between the pipette and the bulk cytosol would not be expected to be prominent and better control of [Na+]i by pipette [Na+] can be achieved. In the present work, we have therefore studied murine ventricular myocytes under voltage-clamp conditions to examine the relationships among pipette [Na+], prior Na+ pump activity, and currents generated by the Na+ pump and the Na+/Ca2+ exchanger, another electrogenic sarcolemmal cation transport system that is sensitive to subsarcolemmal [Na+] (18). We have also determined the changes in [Na+]i at a variety of pipette [Na+] with and without Na+ pump inhibition. Our results demonstrate that neither the development of a substantial gradient between the pipette [Na+] and the [Na+]i nor depletion of K+o at the surface of the Na+ pump or in the T tubule system is likely to account for the observed peak and decay of the Ip after activation of the pump. In addition, we find a similar dependence of the peak Na+/Ca2+ exchanger currents (INa/Ca) on Na+ pump activity in voltage-clamped murine ventricular myocytes. Our results support the hypothesis that there is a subsarcolemmal [Na+] gradient generated by the activity of the Na+ pump, which also affects the [Na+] adjacent to the Na+/Ca2+ exchanger.
| |
METHODS |
|---|
|
|
|---|
Dissociation of adult mouse ventricular myocytes. Mouse ventricular myocytes were dissociated as previously described (33). In brief, hearts were removed from anesthetized mice and immediately mounted on a perfusion system. After perfusion with modified Tyrode solution (Ca2+ free) for 5 min, the heart was digested for 7-12 min with 0.90 mg/ml collagenase D (Boehringer Mannheim Biochemicals) in modified Tyrode solution containing 25 µM CaCl2. The modified Tyrode solution (pH 7.4) contained the following (in mM): 126 NaCl, 4.4 KCl, 1.0 MgCl2, 18 NaHCO3, 11 glucose, 4 HEPES, 30 butanedione monoxime, and 0.13 U/ml insulin, and the solution was gassed with 5% CO2-95% O2. The digested heart was removed from the cannula, and the left ventricle was cut into small pieces in a modified Tyrode solution containing 100 µM Ca2+. These pieces were gently agitated and then incubated in the same solution containing 2% albumin at 30°C for 20 min. The cell suspension was centrifuged at 300 rpm for 3 min, and the pellet of cells was resuspended in modified Tyrode solution containing 200 µM Ca2+ and 2% albumin and allowed to settle for another 20 min at 30°C. Cells were then suspended in culture medium composed of 5% heat-inactivated fetal bovine serum (Hyclone), 47.5% MEM (GIBCO Laboratories), 47.5% modified Tyrode solution, 10 mM pyruvic acid, 4.0 mM HEPES, and 6.1 mM glucose and finally maintained in a 5% CO2 atmosphere at 30°C until use. Isolated cells were used for experiments within 6 h after isolation. All measurements in this study were performed at 25-27°C. In some experiments murine atrial myocytes were isolated with similar techniques.
Measurement of
Ip. The
Ip was measured
using a combination of the method described by Nakao and Gadsby (24)
and a rapid solution-switcher technique (29, 34). Cells were
voltage-clamped (Axopatch 200A, Axon Instruments, Foster City, CA) with
single-suction pipettes, which were made from borosilicate glass tubing
(Corning 7052, 1.65-mm OD, 1.2-mm ID, A-M Systems, Everett, WA) and had initial resistances of 1.5-2.5 M
when filled with pipette
solution. Solutions were designed to minimize all other components of
membrane currents [K+
currents were blocked by replacing intracellular (pipette)
K+ with
Cs+ and tetraethylammonium (TEA)
and adding Ba2+ to extracellular
solution; INa/Ca
were inhibited by including 5 mM
NiCl2 in the bathing solution; the
inward Ca2+ current was blocked by
using a nominal zero-Ca2+ solution
and NiCl2]. The standard
pipette solution contained (in mM) 20 NaCl, 110 CsOH, 110 aspartic
acid, 20 TEA-Cl, 2.0 MgCl2, 5.0 EGTA, 5.0 MgATP, 10 HEPES, 10 glucose, and 5.0 creatine phosphate. The
pH was adjusted to 7.2 with CsOH. Pipette
[Na+] was varied
(5-100 mM) by equimolar adjustment of
Cs+ and
Na+ concentrations. The holding
potential was set to
40 mV throughout the experiments to
inactivate sarcolemmal Na+
channels. We voltage-clamped the myocytes to 0 mV when the
Ip was measured.
Rapid change of the extracellular solution was accomplished with a
rapid solution switcher. This device changes the bulk solution surrounding a myocyte within 4 ms and the
[K+] adjacent to the
sarcolemma with a 90% decay time value
(t90) of 147 ms
for an K+o increase and 260 ms for a K+o decrease in rat myocytes (34).
Ip was activated by resupplying K+ in extracellular
solution containing (in mM) 140 NaCl or 140 Tris · HCl, 5 KCl, 1.0 MgCl2, 2.0 BaCl2, 5.0 NiCl2, 5.0 HEPES, and 5.5 glucose
(pH 7.4 adjusted with NaOH).
Ip was also
evaluated directly by measuring the loss of outward pump current on
rapidly removing K+o. To observe the
influence of Na+ influx through
Na+ channels on
Ip, in some
experiments 12 voltage pulses (from
80 to
10 mV, 50 ms, 5 Hz) were applied before peak
Ip at each time point was recorded. The interval between the last pulse and each measurement of Ip
was 200 ms. Peak
Ip was again
measured by a voltage-clamp technique (held at 0 mV) and activated by
resupplying external K+ for 5 s
using the rapid solution switcher.
To normalize the measured membrane currents to cell surface area,
capacity current transients in response to a 10-mV depolarization pulse
applied from a holding potential of
40 mV were recorded. These
transients were integrated to give total membrane capacitance (pF).
Thus membrane currents were expressed as current density (pA/pF).
Measurement of
INa/Ca. The reverse-exchange
current (Ca2+ in,
Na+ out) was measured by means of
a whole cell voltage-clamp technique (6). Myocytes were voltage-clamped
as described for measurement of
Ip. The cells
were held at a potential of
40 mV. To measure outward exchange
current, the pipette contained (mM) 0.3 MgCl2, 14.0 EGTA, 3.0 MgATP, 5.5 dextrose, and 10 HEPES. Calcium (3.9 mM) was added as
H2CaEGTA to obtain an estimated
free Ca2+ of 100 nM. The solution
pH was adjusted to 7.1 with CsOH, and then CsCl was added to give a
final Cs+ concentration of 130 mM.
Pipette [Na+] was varied from 5 to 40 mM by
adjusting the amount of NaCl added to the pipette solution. To activate
outward reverse-exchange currents, voltage-clamped cells were
superfused in a microstream containing (mM) 138 NaCl, 1.0 MgCl2, 1.0 CaCl2, 11.0 dextrose, and 12 HEPES. The pH was adjusted to 7.4 with NaOH, and then NaCl was added to
give a final Na+ concentration of
145 mM. Outward exchange current was activated when the cell was
abruptly immersed in an adjacent microstream of solution containing
Li+ instead of
Na+, using the solution-switching
device. Preliminary experiments showed that currents elicited with Tris
or Li+ substitution were similar.
To examine the effect of Na+
influx on outward
INa/Ca, we also
applied 12 voltage pulses (from
80 to
10 mV, 50 ms, 5 Hz) to activate Na+ current
(INa+)
200 ms before recording INa/Ca at each
time point, as described previously. For these experiments, nifedipine
(10 µM) was added to the bathing solution to block
Ca2+ current.
The effects of Na+ pump inhibition
on the forward
INa/Ca
(Na+ in,
Ca2+ out) were assessed using a
modification of a previously described method (33). Myocytes were
loaded with fluo 3 by exposure to 1 µM fluo 3-AM at 30°C for 30 min. Myocytes were then voltage-clamped at
80 mV with a single
suction pipette filled with a solution composed of (in mM) 15 NaCl, 100 CsCl, 30 TEA-Cl, 5 MgATP, 10 HEPES, and 5.5 dextrose (pH 7.1 adjusted
with CsOH). The voltage-clamped cell was superfused in a microstream
containing (mM) 138 NaCl, 1.0 MgCl2, 4.4 KCl, 1.08 CaCl2, 2 CsCl, 0.1 BaCl2, 11 dextrose, and 24 HEPES
{pH 7.4 adjusted with NaOH to give a final extracellular [Na+]
([Na+]o)
of 145 mM}. After a train of steady-state conditioning pulses (8 200-ms pulses to 0 mV, 0.25 Hz), the cell was abruptly superfused for 6 s in an adjacent switcher microstream of solution in which 10 mmol/l of
caffeine was added to release sarcoplasmic reticulum Ca2+ and activate the electrogenic
forward
Na+/Ca2+
exchange (3:1 stoichiometry). Intracellular
Ca2+ concentration
([Ca2+]i)
was estimated by assuming that the diastolic
[Ca2+]i
under these experimental conditions was 80 nM (33). The cell was then
exposed for 5 min to 0 K+o solution to inhibit the Na+ pump, and the
protocol was repeated. The effects of
Na+ pump inhibition on the
magnitudes of the peak forward exchange current, the sarcoplasmic
reticulum Ca2+ content (33), and
the magnitude and rate of decline of the caffeine-induced
Ca2+ transient were then measured.
Measurement of
[Na+]i.
[Na+]i
was estimated using the
Na+-sensitive fluorescent dye,
Na+-binding benzofuran
isophthalate fluorescence (SBFI), by modification of previously
described methods (33). Extracellular solution (with or without
K+) and pipette solution (except
for the added SBFI) were the same as that used for the measurements of
Ip. Ventricular
myocytes were dialyzed with 0.5 mM SBFI salt via patch pipettes that
had initial tip resistances of 1.5-3 M
. The myocytes were
clamped at
40 mV and illuminated alternatively at 120 Hz by 340- and 380-nm excitation light (band-pass filters P10-340 and
P10-380, Corion, Holliston, MA) using an optical switcher
(DX-1000, Solamere Technology Group, Salt Lake City, UT), and the
resulting fluorescence signals at 510 nm (P10-510 Corion) were
detected with a photomultiplier (SFX-2, Solamere Technology Group). The
ratio of two signals corresponding to excitation wavelengths at 340 and
380 nm was used as an indicator of
[Na+]i.
Background fluorescence measured after a gigaseal was obtained just
before the rupture of the membrane was zeroed at excitation wavelengths
of 340 and 380 nm, respectively. All recordings started 10 min after
establishment of the whole cell configuration to allow sufficient time
for diffusion of SBFI from pipettes into myocytes.
When the Na+ pump and
Na+/Ca2+
exchange were inhibited by 0 K+o and
Ni2+,
[Na+]i
was approximately equal to the pipette
[Na+]. For
calibration, myocytes were bathed in
zero-K+o solution for 10 min
and dialyzed with pipette solutions containing 3.75, 7.5, 10, and 20 mM
Na. The fluorescence ratio was then recorded before and 5 min after
exposure of a cell to 5 mM K+o to
reactivate the Na+ pump. The
relationship between the fluorescence ratio (R) and pipette
[Na] with the Na+ pump
inhibited was fitted to the equation:
[Na+] = Kd × (R
Rmin)/(Rmax
R). With the use of the resulting calibration curve, the
fluorescence ratios were then converted to
[Na+]i values.
Statistics. Physiological recordings were digitized online with a DigiData 1200 Interface (Axon Instruments) and stored on disk. The digitized data were analyzed with pCLAMP6 (Axon Instruments) and ORIGIN (Microcal Software). All curve fitting was performed using ORIGIN. Results are presented as means ± SE, and statistical differences were determined by ANOVA and unpaired or paired t-tests where appropriate. Differences were considered significant at P < 0.05.
| |
RESULTS |
|---|
|
|
|---|
Transient and steady-state Ip. In isolated mouse ventricular myocytes incubated in zero-K+o solution, Ip was activated by resupplying K+o with the rapid solution switcher. As shown in Fig. 1A, mouse ventricular myocytes exhibited a transient peak current within <1 s, followed by a decline to a near steady-state level, which plateaued 2 min after the pump was reactivated. The steady-state Ip could also be measured by abruptly exposing a clamped myocyte to 0 [K+]i, as shown in Fig. 1B. Note that Ip decayed to 0 within ~400 ms of reducing [K+]i to 0. This time course is consistent with the rate of diffusion of K+ from the external sarcolemmal surface to the bulk solution (34) and the nonlinear dependence of pump rate on [K+]o.
|
Both peak Ip and steady-state Ip were eliminated in the presence of 2 mM ouabain (not shown). Peak Ip increased in a time-dependent manner over 4-5 min after exposure to zero-K+o solution following establishment of a gigaseal. However, the steady-state Ip did not show any time-dependent change when the pipette [Na+] was similar to the resting [Na+]i (Fig. 2). The integral of the area under the current transient as it decayed over a 2-min recording period from peak to steady-state Ip was 3.9 ± 0.3 nC (n = 16) when the pipette [Na+] was 20 mM. On the basis of the stoichiometry of the electrogenic Na+-K+ pump (3 Na+ exchanged for 2 K+), the amount of Na+ pumped out during the Ip transient was 0.12 ± 0.01 pmol or ~12% of the initial total intracellular Na+, assuming that the initial [Na+]i is equal to the pipette [Na+] and the average cell volume is 50 pl (cell length = 125 µm, width = 20 µm, thickness = 20 µm).
|
Both peak Ip and steady-state Ip were dependent on the pipette [Na+] (Fig. 3). The K0.5 values (concentration of pipette [Na+] required for 50% stimulation of pump activity estimated from a Hill plot) for peak Ip and steady-state Ip were 14 and 49 mM, respectively. The mean value of steady-state Ip at a pipette [Na+] of 20 mM (0.36 ± 0.06 pA/pF, n = 5) is quite close to that obtained directly by measuring the loss of outward pump current on exposure to zero-[K+]o solution (Fig. 1B). An important point is that peak Ip was substantially greater than steady-state Ip, even at a pipette [Na+] similar to resting cytoplasmic [Na+] (~16 mM) in unclamped cells when no gradient in [Na+] between cytosol and pipette would be expected. For example, the magnitude of steady-state Ip at a pipette [Na+] of 20 mM is only 24% of the corresponding peak Ip and lower than peak Ip at a pipette [Na+] of 5 mM, suggesting that [Na+] in the subsarcolemmal space (close to intracellular Na+-binding sites of pump) in resting mouse ventricular myocytes is <5 mM.
|
Changes in [Na+]i during activation of the pump. Several explanations could account for the finding that peak Ip is greater than steady-state Ip. One explanation mentioned above is that there is a substantial [Na+] gradient between subsarcolemmal space and bulk cytoplasm in mouse ventricular myocytes. The other is that a large [Na+] gradient develops between the pipette solution and cytoplasm of the clamped myocytes when the Na+ pump is activated. To examine the second possibility, we estimated the changes in cytosolic [Na+] during the inhibition and activation of the Na+ pump at various pipette [Na+]. The results are shown in Fig. 4. The fluorescence ratio (F340/F380) increased with increase in the pipette [Na+] over the range of 3.75-20 mM (Fig. 4A). With the Na+ pump inhibited by zero [K+]o and Na+/Ca2+ exchange inhibited by Ni2+, we assumed that [Na+]i was equal to pipette [Na+]. The resulting calibration curve yielded values for Kd, Rmin, and Rmax (Fig. 4A) consistent with previous reports of in vivo characteristics of SBFI (8, 27). The [Na+]i was then estimated in zero [K+]o and in normal [K+]o by the observed F340/F360 before and 5 min after resupply of [K+]o (Fig. 4B). The cytosolic [Na+] was similar before and after activation of the Na+ pump, with a maximum difference of ~3 mM noted at a pipette [Na+] of 20 mM. These differences in [Na+] between pipette and bulk cytoplasm cannot account for the large difference between peak Ip and steady-state Ip (Fig. 3). This finding is consistent with the presence of a substantial [Na+] gradient between the bulk cytoplasm and subsarcolemmal space.
|
Effects of [Na+]o and [K+]o on pump current. To explore the possibility that extracellular Na+ influx (leak) from the bath solution may influence [Na+] in the subsarcolemmal space, Ip was also measured in the absence of extracellular Na+. Removal of extracellular Na+ during exposure to zero [K+]o did not reduce Ip magnitudes induced by subsequent exposure to 5 mM [K+]o (Fig. 5A). In fact, peak Ip was higher in zero extracellular Na+ than in normal extracellular Na+. The increased peak Ip in the absence of extracellular Na+ is probably due to an increase in the affinity of the pump for external K+ on removal of external Na+ (24). With zero Na+ in the pipette and normal extracellular Na+, small pump currents could be detected (relative peak Ip 8.3%, relative steady-state Ip 2.6%), which is consistent with the results of Nakao and Gadsby (24) and consistent with the conclusion that Na+ influx has little effect on subsarcolemmal [Na+] in resting cells.
|
It has been reported that Na+ pumps are located in both peripheral sarcolemma and T tubules of cardiomyocytes (19). Accordingly, the current transient could be caused in part by the depletion of external K+ in the T tubules. To examine this possibility, we also measured Ip at an K+o of 10 mM. Figure 5B shows that 10 mM [K+]o did not affect the Ip amplitudes. A transient peak Ip was also observed with a K+o = 100 mM (data not shown). Furthermore, we observed a transient peak Ip with a subsequent decline to a steady-state Ip in mouse atrial myocytes, which lack T tubules (data not shown). These results suggest that an inward Na+ leak does not contribute significantly to the maintenance of subsarcolemmal [Na+] in cells clamped in zero K+o and that depletion of K+ in T tubules is not a factor responsible for the observed decay of the pump current. Na+ influx through Na+ channels might be expected to influence subsarcolemmal [Na+] (13, 14). As shown in Fig. 6, induction of a series of INa+ significantly increased the magnitude of the pump current early after exposure to zero K+o but did not influence the plateau value after more prolonged pump inhibition.
|
Outward INa/Ca. To provide further evidence supporting the existence of a subsarcolemmal [Na+] gradient, we measured the currents produced by the Na+/Ca2+ exchanger, another electrogenic sarcolemma ion transporter that is influenced by subsarcolemmal [Na+]. Outward INa/Ca was activated by rapidly removing external Na+ with a fast solution switcher, as illustrated in Fig. 7. The outward INa/Ca reached a plateau ~15 min after a whole cell recording mode in zero [K+]o solution was obtained. If we first immersed the clamped cell in normal [K+]o solution for 10 min to allow adequate cell dialysis with EGTA and then measured the time course of INa/Ca in zero [K+]o, it reached a plateau after 5 min of exposure to zero [K+]o (Fig. 8A), similar to the time in zero [K+]o required for plateau of peak Ip. Reexposure of the cell to normal [K+]o caused INa/Ca to decrease to 15% of the plateau value in 2 min after [K+]o was reapplied (Fig. 8B). Induction of a series of INa+ increased the magnitude of INa/Ca early after exposure to zero [K+]o but did not affect its magnitude at plateau, as was observed with the effects of INa+ on Ip (Fig. 8C).
|
|
In Fig. 9 it is shown that the magnitude of outward INa/Ca is highly Na+ dependent and that INa/Ca amplitudes measured with the activated Na+ pump (in normal [K+]o) were significantly lower than with the inhibited Na+ pump (in zero [K+]o). The pattern of alteration in outward INa/Ca in normal [K+]o and zero [K+]o is consistent with that observed in our Ip studies, further supporting the existence of a subsarcolemmal [Na] gradient.
|
Inward INa/Ca.
Figure 10 shows an example of the effects
of Na+ pump inhibition on the
inward INa/Ca
resulting from forward
Na+/Ca2+
exchange, activated by abrupt release of
Ca2+ from the sarcoplasmic
reticulum by caffeine. Activation of
INa/Ca slightly
preceded the rise in cytosolic
Ca2+ due to caffeine-induced
release of Ca2+ from the
sarcoplasmic reticulum, and analysis of unfiltered
INa/Ca and
[Ca2+]i
transients showed that the peak
INa/Ca
consistently occurred ~70 ms before the peak
[Ca2+]i.
The
[Ca2+]i,
as monitored by fluo 3 fluorescence, then declined as
INa/Ca declined
from a peak value. After inhibition of the
Na+ pump by exposure to zero
K+o for 5 min, a greater [Ca2+]i
was observed after caffeine exposure (Fig.
10B), consistent with increased
loading of the sarcoplasmic reticulum via reverse Na+/Ca2+
exchange during the preceding voltage-clamp pulses. However, the peak
INa/Ca observed
during the caffeine-induced Ca2+
transient was diminished. Average results are shown in Table 1. The peak
[Ca2+]i
of the caffeine-induced transient and the sarcoplasmic reticulum Ca2+ content were increased by
~40% after pump inhibition, yet the magnitude of the peak
INa/Ca was
decreased significantly. In addition, the
of
INa/Ca decay and
[Ca2+]i
decline were increased. These findings are consistent with a rise in
the subsarcolemmal Na+ caused by
Na+ pump inhibition and a
resulting reduction in forward
Na+/Ca2+
exchange despite an increase in
[Ca2+]i.
|
|
| |
DISCUSSION |
|---|
|
|
|---|
Factors contributing to the transient nature of abruptly activated Ip in intact ventricular myocytes. Our findings clearly indicate that in voltage-clamped adult murine ventricular myocytes, abrupt reactivation of the Na+ pump by rapid resupply of K+o results in a Ip that peaks and then declines to a steady-state value. This phenomenon has not been previously characterized in mouse ventricular myocytes, although it has been previously documented in other isolated cardiac myocyte preparations, including rabbit Purkinje and ventricular cells (4) and cultured sheep Purkinje cardioballs (10). Assuming the cytosolic Na+ is controlled by the pipette [Na+], this would imply a nonlinear relationship between pump rate and cytosolic [Na+] after abrupt activation of the pump. However, Eisner et al. (9) reported a linear relation between intracellular Na+ activity (aiNa+) and Ip after activation of pump current by resupply of Rb+ in intact Purkinje fibers. This difference may indicate that a slower rate of pump reactivation is achieved in intact tissue as contrasted with isolated cells due to the time required to exchange the bath and for diffusion of activating cation through the tissue.
The magnitudes of the steady-state Ip that we measured in mouse myocytes at 26°C are similar to those reported by Nakao and Gadsby (24) in guinea pig myocytes at 35°C, at comparable [Na+]i. These investigators did not measure effects of abrupt reactivation of Ip. In our experiments, we have examined the relationship between peak and steady-state Ip at a variety of different pipette [Na+], and we have clearly documented that the peak Ip is substantially greater than the steady-state pump current, even at pipette [Na+] of 100 mM. The peak current measured at a pipette [Na+] of 100 mM was 2.1 pA/pF, a value similar to that predicted based on the pump density and maximal turnover rate (~2.8 pA/pF, see Ref. 22). A pipette [Na+] of 25-30 mM was required to produce a steady-state Ip equal to a peak Ip produced at a pipette [Na+] of 5 mM, a value well below the normal resting [Na+]i of 16 mM in these cells. These findings imply that there is a substantial gradient between the pipette [Na+] and the subsarcolemmal [Na+], which is sensed by the Na+ pump.
Our results indicate that only a small component of this gradient could
be due to a gradient between the pipette and the bulk cytosol.
Measurements of cytosolic
[Na+] by means of the
fluorescent Na+-sensitive dye SBFI
indicate that when the
[Na+] in the pipette
is higher than the resting
[Na+] in the cell (20 vs. 16 mM), a small
[Na+] gradient is
apparent. However, it is clear that this is too small to account for
the apparent differences in the peak and steady-state
Ip at pipette
[Na+]
20 mM
consistent with the analysis of Carmeliet (5). The apparent difference
in peak and steady-state
Ip also does not appear to be accounted for by a leak of
Na+ into the subsarcolemmal space
during exposure to zero
[K+]o,
because it was not affected by elimination of extracellular Na+. Furthermore, depletion of
K+ in the T tubules or at the
external surface of the Na+ pump
site appears unlikely. In our experiments, peak and steady-state Ip were not
affected by increasing the K+o
concentration used to activate the
Na+ pump, and we also observed
peak transients under similar experimental conditions in atrial
myocytes that lack T tubules. The conclusion that T tubules are not
necessary to explain this phenomenon is also supported by the results
of Bielen et al. (4), who noted transient
Ip in Purkinje
cells that also lack T tubules. Thus our results provide further
support for the existence of a
[Na+] gradient between
the bulk cytoplasm and the inner surface of the
Na+ pump transport site.
Based on the experiments of LeBlanc and Hume (13), Lederer et al. (14) have speculated about the size of the Na+-restricted space (Na+ fuzzy space). In our experiments, integration of the Ip transient allowed an estimation that the total amount of Na+ extruded from the cell during the transient was equivalent to ~12% of the initial Na+, at a pipette [Na+] = 20 mM. However, it is clear that a substantial component of this total current transient reflects movement of Na+ from the pipette to the cytosol and from the cytosol to the subsarcolemmal space. Therefore, it does not appear to be possible to estimate the absolute size of the Na+ "fuzzy space" from examination of the integral of the Ip. It is worth noting that in our experiments, activation of the INa+ before measurement of the peak Na+ pump and exchanger currents (Figs. 6 and 8C) increased these currents substantially early after exposure to zero K+o, when the subsarcolemmal [Na+] was presumably still low. However, after more prolonged inhibition of the pump, with presumed equilibration between subsarcolemmal [Na+] and cytosolic [Na+], no effect of INa+ on pump and exchanger currents was apparent. This finding suggests that Na+ entering the cell via the Na+ channel may increase Na+ concentration in the fuzzy space when the pump is not inhibited, as suggested by LeBlanc and Hume (13). However, it is not clear that Na+ entering the cell by other Na+ influx pathways gains immediate access to the restricted space sensed by the Na+ pump, since the resting cytosolic [Na+] (16 mM) in nonclamped cells appears higher than the [Na+] sensed by the Na+ pump (<5 mM). This would not be expected if Na+ entering the resting cell across the sarcolemma had to traverse this space to gain access to the cytosol.
The apparent dependence of the Ip on [Na+]i in our experiments allowed an estimation of the Kd for pump activation by Na+ of 14.3 mM when the peak current was used as an estimate of the pump activity versus 49 mM when the steady-state current was used as an indicator of pump activity. The former value is much closer to the Kd estimated in the isolated vesicle or partially purified enzyme studies of the Na+-K+-ATPase. This observation also provides further support for the idea that the Na+ activity sensed by the Na+ pump is more accurately reflected by peak Ip than by the steady-state current. This finding emphasizes the importance of using the peak Ip to estimate Na+ pump activity when voltage-clamp techniques are being applied to assess Na+ pump density in ventricular myocytes (4).
Influence of Na+ pump activity on INa/Ca. Previous investigators have used voltage-clamp techniques to assess Na+/Ca2+ exchanger activity. In work by Miura and Kimura (20), voltage-clamped myocytes were exposed to zero-Ca2+ and -Na+ extracellular solutions, and then extracellular Ca2+ was abruptly resupplied, resulting in the generation of an outward current. This approach has been used to determine the influence of intracellular Na+ on INa/Ca magnitude, and in all these experiments, the Na+ pump was completely inhibited by exposure to zero [K+]o during the current measurements.
Chin et al. (6) developed an alternative approach. In their experiments, voltage-clamped myocytes were abruptly exposed to zero extracellular Na+ in the presence of extracellular Ca2+, resulting in the generation of an outward current due to reverse Na+/Ca2+ exchange. Chin et al. (6) observed that INa/Ca quickly decayed if the Na+ pump was reactivated by a resupply of K+o. In these experiments, which used voltage-clamped guinea pig ventricular myocytes, the pipette [Na+] was considerably higher than the resting [Na+], and a dependence of the exchanger current on Na+ pump activity was attributed to an inability to control bulk cytosol [Na+] with the pipette [Na+] in the presence of Na+ pump activity.
In our experiments, a marked dependence of INa/Ca on the previous activity of the Na+ pump was noted even at a pipette [Na+] equal to or even below the normal resting cytosolic [Na+] in mouse ventricular myocytes. Indeed, the relationship between the peak INa/Ca measured after a period of inhibition of the Na+ pump and in the absence of pump inhibition was similar to that observed between the peak and steady-state Ip measurements (compare Figs. 3B and 9). Furthermore, the time required to reach a plateau of INa/Ca and peak Ip after inhibition of the Na+ pump was similar when adequate time for diffusion of EGTA to buffer Ca2+ was allowed before Na+ pump inhibition was instituted. (If Ca2+ is not adequately buffered with EGTA during measurement of INa/Ca, Ca2+ influx raises [Ca2+]i, reducing the Ca2+ gradient and causing contraction). The INa/Ca also demonstrated a similar time course of decay to a steady-state value after reactivation of the Na+ pump.
The experiments shown in Fig. 10 and Table 1 also provide evidence that the magnitude of forward Na+/Ca2+ exchange is influenced by Na+ pump activity. It is of interest that the peak INa/Ca is similar to the peak Ip (Fig. 9 and Fig. 3B). This finding is consistent with work suggesting that the site density and turnover rate for the Na+/Ca2+ exchanger and the Na+-K+-ATPase are similar (26). Taken together, the similar dependence of the Ip and the INa/Ca on prior Na+ pump activity is very suggestive that both transporters are sensing a similar subsarcolemmal [Na+], which is lower than the bulk cytosolic [Na+]. Bielen et al. (4) have also reported a relationship between Ip and INa/Ca during the decline of Ip after reactivation of the pump in Purkinje cells, and Main et al. (18) have shown an influence of pump activity on Na+/Ca2+ exchange in voltage-clamped guinea pig ventricular myocytes. In addition, recent evidence suggests that there may be colocalization of the Na+ pump and Na+/Ca2+ exchanger in the membrane of cardiac and smooth muscle myocytes (19, 23). This colocalization may result from the binding of these ion transporters to the cytoskeletal protein ankyrin (15, 17).
Physiological implications of our findings. A number of investigators have noted a dissociation among Na+ pump activity, changes in bulk [Na+]i, and alteration of Ca2+ homeostasis during recovery from Na+ pump inhibition (2). We previously reported that during recovery from Na+ pump inhibition in cultured chick embryo myocytes, intracellular Na+ measured with 24Na+ returned to normal levels more slowly than Na+/Ca2+ exchange and contractility (3). Eisner et al. (9) also noted a more rapid decay in twitch tension than aiNa measured with a Na+-sensitive microelectrode in voltage-clamped Purkinje fibers after reactivation of the Na+ pump. Levi et al. (16) have also noted a dissociation between changes in bulk [Na+]i and contractility during washout of pump inhibition in isolated ventricular myocytes. The presence of a subsarcolemmal space in which Na+/Ca2+ exchanger activity is more dependent on Na+ pump activity than on bulk cytosolic Na+ concentration could account for these findings (2, 3). This concept could also explain why inotropic effects of cardiac glycosides may be seen in tissues at a time when apparent inhibition of the Na+ pump manifested by change in cellular [Na+] is very minor or nondetectable (1, 16).
Whereas our results do support the functional presence of so-called
Na+ fuzzy space, there are still
some issues regarding the possible existence of this space that remain
unresolved. For example, pump, exchanger, and ion channel transmembrane
currents that have time constants of the order of milliseconds may be
measured by voltage-clamp, yet the rate of decay of the
Ip and the
INa/Ca, allegedly
attributable to limitation of diffusion in the subsarcolemmal
space, is of the order of seconds to minutes. Several factors might
account for this apparent discrepancy. First, it is possible that the limitation of diffusion of Na+
adjacent to the Na+ pump or the
Na+/Ca2+
exchanger transporter site is limited to a very small area, and that a
subsarcolemmal diffusion barrier does not exist over the major portion
of the sarcolemma. It also appears that the restriction of diffusion is
primarily for Na+, possibly due to
binding of Na+ by intracellular
buffers (11), and that restriction of movement of other intracellular
ions that can carry currents such as
H+,
Cl
,
Ca2+, and
K+ is less marked. Certainly,
based on the results shown in Fig. 10 and the findings of Delbridge et
al. (7) and Trafford et al. (32), the movement of
Ca2+ from the cytosol to the
Na+/Ca2+
exchanger can occur very rapidly. Consistent with the findings of
Trafford et al. (32), we noted a slight delay between the activation of
forward INa/Ca
and the rise in [Ca2+]
during a caffeine transient, consistent with some diffusion limitation
from the cytosol to the subsarcolemmal space for
Ca2+. However, the access of
cytosolic Ca2+ to the exchanger
sites appears much less restricted than that of
Na+. This apparent limitation of
diffusion of Na+ to (and perhaps
from) this site is paradoxical in view of the reported more rapid
diffusion of Na+ than
Ca2+ in bulk muscle cell cytoplasm
(12). This paradox has been emphasized previously (2, 14) and may
reflect microdomain complexity of the
Na+/Ca2+
exchanger and Na+ pump sites.
Resolution of these issues will require further experimentation, including possible measurement of subcellular
Na+ gradients by physical techniques.
| |
ACKNOWLEDGEMENTS |
|---|
We are indebted to Pam Larson for preparation of the manuscript.
| |
FOOTNOTES |
|---|
This study was supported in part by National Heart, Lung, and Blood Institute Grants HL-30478, HL-53773, and HL-52338. Z. Su is a visiting scholar from Hunan Medical University, P. R. China.
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. §1734 solely to indicate this fact.
Address for reprint requests: W. H. Barry, Division of Cardiology, Univ. of Utah Health Sciences Center, 50 North Medical Dr., Salt Lake City, UT 84132.
Received 23 March 1998; accepted in final form 15 July 1998.
| |
REFERENCES |
|---|
|
|
|---|
1.
Akera, T.,
R. Bennett,
M. K. Olgaard,
and
T. M. Brody.
Cardiac Na+, K+-adenosine triphosphatase inhibition by ouabain and myocardial Na: a computer simulation.
J. Pharmacol. Exp. Ther.
199:
287-297,
1976
2.
Barry, W. H.
Is "fuzzy space" necessary for Ca2+ extrusion on the Na+-Ca2+ exchanger in cardiac myocytes?
J. Mol. Cell. Cardiol.
25:
641-643,
1993[Medline].
3.
Barry, W. H.,
S. Bierdert,
D. S. Miura,
and
T. W. Smith.
Changes in cellular Na+, K+, and Ca2+ contents, monovalent cation transport rate, and contractile state during washout of cardiac glycosides from cultured chick heart cells.
Circ. Res.
49:
141-149,
1981
4.
Bielen, F. V.,
H. G. Glitsch,
and
F. Verdonck.
Changes of the subsarcolemmal Na+ concentration in internally perfused cardiac cells.
Biochimica et Biophysica Acta
1065:
269-271,
1991[Medline].
5.
Carmeliet, E.
A fuzzy subsarcolemmal space for intracellular Na+ in cardiac cells?
Cardiovasc. Res.
26:
433-442,
1992[Medline].
6.
Chin, T. K.,
K. W. Spitzer,
K. D. Philipson,
and
J. H. B. Bridge.
The effect of exchanger inhibitory peptide (XIP) on Na+/Ca2+ exchange current in guinea pig ventricular cells.
Circ. Res.
72:
497-503,
1993
7.
Delbridge, L.,
J. W. M. Bassani,
and
D. M. Bers.
Steady-state twitch Ca2+ fluxes and cytosolic Ca2+ buffering in rabbit ventricular myocytes.
Am. J. Physiol.
270 (Cell Physiol. 39):
C192-C199,
1996
8.
Donoso, P.,
J. G. Mill,
S. C. O'Neill,
and
D. A. Eisner.
Fluorescence measurements of cytoplasmic and mitochondrial sodium concentration in rat ventricular myocytes.
J. Physiol. (Lond.)
448:
493-509,
1992
9.
Eisner, D. A.,
W. J. Lederer,
and
R. D. Vaughan-Jones.
The dependence of sodium pumping and tension on intracellular Na activity in voltage-clamped sheep purkinje fibers.
J. Physiol. (Lond.)
317:
163-187,
1981
10.
Glitsch, H. G.,
W. Schwarz,
and
A. Tappe.
Cardiac Na+ pump current-voltage relationships at various transmembrane gradients of the pumped cations.
Biochim. Biophys. Acta
1278:
137-146,
1996[Medline].
11.
Isenberg, G.,
and
M. F. Wendt-Gallitelli.
X-ray microprobe analysis of sodium concentration reveals large transverse gradients from the sarcolemma to the center of voltage-clamped guinea pig ventricular myocytes (Abstract).
J. Physiol. (Lond.)
420:
86P,
1990.
12.
Kushmerick, M. J.,
and
R. J. Podolsky.
Ionic mobility in muscle cells.
Science
166:
1297-1298,
1969
13.
LeBlanc, N.,
and
J. R. Hume.
Na current-induced release of Ca2+ from cardiac sarcoplasmic reticulum.
Science
248:
372-376,
1990
14.
Lederer, W. J.,
E. Niggli,
and
R. W. Hadley.
Sodium-calcium exchange in excitable cells: fuzzy space.
Science
248:
283,
1990
15.
Lee, D.,
X. Chen,
and
P. R. Smith.
Na+/K+ ATPase is linked to ankyrin and spectrin in arterial smooth muscle cells (Abstract).
J. Gen. Physiol.
108:
13a-14a,
1996.
16.
Levi, A. J.,
M. R. Boyett,
and
C. O. Lee.
The cellular actions of digitalis glycosides on the heart.
Prog. Biophys. Mol. Biol.
62:
1-54,
1994[Medline].
17.
Li, Z.,
E. P. Burke,
J. S. Frank,
V. Bennett,
and
K. D. Philipson.
The cardiac Na+-Ca2+ exchanger binds to the cytoskeletal protein ankyrin.
J. Biol. Chem.
268:
11489-11491,
1993
18.
Main, M. J.,
C. J. Grantham,
and
M. B. Cannell.
Changes in subsarcolemmal sodium concentration measured by Na-Ca2+ exchanger activity during Na-pump inhibition and
-adrenergic stimulation in guinea-pig ventricular myocytes.
Pflügers Arch.
435:
112-118,
1997[Medline].
19.
McDonough, A. A.,
Y. Zhang,
V. Shin,
and
J. S. Frank.
Subcellular distribution of Na pump isoform subunits in mammalian cardiac myocytes.
Am. J. Physiol.
270 (Cell Physiol. 39):
C1221-C1227,
1996
20.
Miura, Y.,
and
J. Kimura.
Na+/Ca2+ exchange current. Dependence on internal Ca2+ and Na and competitive binding of external Na and Ca.
J. Gen. Physiol.
93:
1129-1145,
1989
21.
Mogul, D. J.,
D. H. Singer,
and
R. E. Ten Eick.
Ionic diffusion in voltage-clamped isolated cardiac myocytes.
Biophys. J.
56:
565-577,
1989
22.
Mogul, D. J.,
D. H. Singer,
and
R. E. Ten Eick.
Dependence of Na+-K+ pump current on internal Na+ in mammalian cardiac myocytes.
Am. J. Physiol.
259 (Heart Circ. Physiol. 28):
H488-H496,
1990
23.
Moore, E. D. W.,
E. F. Etter,
K. D. Philipson,
W. A. Carrington,
K. E. Fogarty,
L. M. Lifshitz,
and
F. S. Fay.
Coupling of the Na+/Ca2+ exchanger, Na+/K+ pump and sarcoplasmic reticulum in smooth muscle.
Nature
365:
657-660,
1993[Medline].
24.
Nakao, M.,
and
D. C. Gadsby.
[Na] and [K] dependence of the Na+/K pump current-voltage relationship in guinea pig ventricular myocytes.
J. Gen. Physiol.
94:
539-565,
1989
25.
Philipson, K. D.,
and
A. Y. Nishimoto.
ATP-dependent Na+ transport in cardiac sarcolemmal vesicles.
Biochim. Biophys. Acta
733:
133-141,
1983[Medline].
26.
Powell, T.,
A. Noma,
T. Shioya,
and
R. Z. Kozlowski.
Turnover rate of the cardiac Na+-Ca2+ exchanger in guinea-pig ventricular myocytes.
J. Physiol. (Lond.)
472:
45-53,
1993
27.
Satoh, H.,
H. Hayashi,
N. Noda,
H. Terada,
A. Kobayashi,
Y. Yamashita,
T. Kawai,
M. Hirano,
and
N. Yamazaki.
Quantification of intracellular free sodium ions by using a new fluorescent indicator, sodium-binding benzofuran isophthalate in guinea pig myocytes.
Biochem. Biophys. Res. Commun.
175:
611-616,
1991[Medline].
28.
Semb, S. O.,
and
O. M. Sejersted.
Fuzzy space and control of Na+, K+-pump rate in heart and skeletal muscle.
Acta Physiol. Scand.
156:
213-224,
1996[Medline].
29.
Spitzer, K. W.
An improved rapid solution switcher for use with single isolated cells (Abstract).
J. Physiol. (Lond.)
476:
10P,
1994.
30.
Stimers, J. R.,
S. Liu,
and
T. A. Kinard.
Effect of Nai on activity and voltage dependence of the Na/K pump in adult rat cardiac myocytes.
J. Membr. Biol.
135:
39-47,
1993[Medline].
31.
Thomas, R. C.
Electrogenic sodium pump in nerve and muscle cells.
Physiol. Rev.
52:
563-594,
1972
32.
Trafford, A. W.,
M. D. Diaz,
S. C. O'Neill,
and
D. A. Eisner.
Comparison of subsarcolemmal and bulk calcium concentration during spontaneous calcium release in rat ventricular myocytes.
J. Physiol. (Lond.)
488:
577-586,
1995[Medline].
33.
Yao, A.,
Z. Su,
A. Nonaka,
I. Zubair,
L. Lu,
K. D. Philipson,
J. H. B. Bridge,
and
W. H. Barry.
The effects of over-expression of the Na+/Ca2+ exchanger on [Ca2+]i transients in murine ventricular myocytes.
Circ. Res.
82:
657-665,
1998
34.
Yao, A.,
K. W. Spitzer,
N. Ito,
M. Zaniboni,
B. H. Lorell,
and
W. H. Barry.
The restriction of diffusion of cations at the external surface of cardiac myocytes varies between species.
Cell Calcium
22:
431-438,
1997[Medline].
This article has been cited by other articles:
![]() |
V. E. Bondarenko, G. P. Szigeti, G. C. L. Bett, S.-J. Kim, and R. L. Rasmusson Computer model of action potential of mouse ventricular myocytes Am J Physiol Heart Circ Physiol, September 1, 2004; 287(3): H1378 - H1403. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. A. Golovina, H. Song, P. F. James, J. B. Lingrel, and M. P. Blaustein Na+ pump alpha 2-subunit expression modulates Ca2+ signaling Am J Physiol Cell Physiol, February 1, 2003; 284(2): C475 - C486. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. G. Glitsch Electrophysiology of the Sodium-Potassium-ATPase in Cardiac Cells Physiol Rev, October 1, 2001; 81(4): 1791 - 1826. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. H. Barry Na+-Ca2+ Exchange in Failing Myocardium : Friend or Foe? Circ. Res., September 29, 2000; 87(7): 529 - 531. [Full Text] [PDF] |
||||
![]() |
A. Arnon, J. M. Hamlyn, and M. P. Blaustein Ouabain augments Ca2+ transients in arterial smooth muscle without raising cytosolic Na+ Am J Physiol Heart Circ Physiol, August 1, 2000; 279(2): H679 - H691. [Abstract] [Full Text] [PDF] |
||||
![]() |
|