AJP - Heart Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 280: H2639-H2648, 2001;
0363-6135/01 $5.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (15)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nelson, G. S.
Right arrow Articles by Tyberg, J. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nelson, G. S.
Right arrow Articles by Tyberg, J. V.
Vol. 280, Issue 6, H2639-H2648, June 2001

Compression of interventricular septum during right ventricular pressure loading

Gregory S. Nelson1, Ezzeldin Y. Sayed-Ahmed2, Carol A. Gibbons Kroeker1, Yi-Hui Sun1, Henk E. D. J. Ter Keurs1, Nigel G. Shrive1, and John V. Tyberg1

1 Departments of Medicine, Physiology and Biophysics and Civil Engineering, University of Calgary, Calgary, Alberta T2N 4N1, Canada; and the 2 Department of Civil Engineering, Ain Shams University, Cairo 11331, Egypt

The interventricular septum, which flattens and inverts in conditions such as pulmonary hypertension, is considered by many to be an unstressed membrane, in that its position is assumed to be determined solely by the transseptal pressure gradient. A two-dimensional finite element model was developed to investigate whether compression and bending moments (behavior incompatible with a membrane) exist in the septum during diastole under abnormal loading, i.e., pulmonary artery (PA) constriction. Hemodynamic and echocardiographic data were obtained in six open-chest anesthetized dogs. For both control and PA constriction, the measured left ventricular and right ventricular pressures were applied to a residually stressed mesh. Adjustments were made to the stiffness and end-bending moments until the deformed and loaded residually stressed mesh matched the observed configuration of the septum. During PA constriction, end-bending moments were required to obtain satisfactory matches but not during control. Furthermore, substantial circumferential compressive stresses developed during PA constriction. Such stresses might impede septal blood flow and provoke the unexplained ischemia observed in some conditions characterized by abnormal septal motion.

finite element analysis; interventricular septum; mechanics; compressive stress


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
J. T. Marcus, C. T.-J. Gan, J. J.M. Zwanenburg, A. Boonstra, C. P. Allaart, M. J.W. Gotte, and A. Vonk-Noordegraaf
Interventricular Mechanical Asynchrony in Pulmonary Arterial Hypertension Left-to-Right Delay in Peak Shortening Is Related to Right Ventricular Overload and Left Ventricular Underfilling.
J. Am. Coll. Cardiol., February 19, 2008; 51(7): 750 - 757.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
A. Vonk-Noordegraaf, J.-W. Lankhaar, M. J.W. Gotte, J. T. Marcus, P. E. Postmus, and N. Westerhof
Magnetic resonance and nuclear imaging of the right ventricle in pulmonary arterial hypertension
Eur. Heart J. Suppl., December 1, 2007; 9(suppl_H): H29 - H34.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
B. T. A. Esch, J. M. Scott, M. J. Haykowsky, D. C. McKenzie, and D. E. R. Warburton
Diastolic ventricular interactions in endurance-trained athletes during orthostatic stress
Am J Physiol Heart Circ Physiol, July 1, 2007; 293(1): H409 - H415.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. A. Gibbons Kroeker, S. Adeeb, J. V. Tyberg, and N. G. Shrive
A 2D FE model of the heart demonstrates the role of the pericardium in ventricular deformation
Am J Physiol Heart Circ Physiol, November 1, 2006; 291(5): H2229 - H2236.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. A. Gibbons Kroeker, S. Adeeb, N. G. Shrive, and J. V. Tyberg
Compression induced by RV pressure overload decreases regional coronary blood flow in anesthetized dogs
Am J Physiol Heart Circ Physiol, June 1, 2006; 290(6): H2432 - H2438.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
T. Arts, T. Delhaas, P. Bovendeerd, X. Verbeek, and F. W. Prinzen
Adaptation to mechanical load determines shape and properties of heart and circulation: the CircAdapt model
Am J Physiol Heart Circ Physiol, April 1, 2005; 288(4): H1943 - H1954.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
B. P. J. Leeuwenburgh, W. A. Helbing, P. Steendijk, P. H. Schoof, and J. Baan
Effects of acute left ventricular unloading on right ventricular function in normal and chronic right ventricular pressure-overloaded lambs
J. Thorac. Cardiovasc. Surg., March 1, 2003; 125(3): 481 - 490.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
S. Cazeau, C. Alonso, G. Jauvert, A. Lazarus, and P. Ritter
Cardiac resynchronization therapy
Europace, January 1, 2003; 5(s1): S42 - S48.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online