1 Division of Pulmonary and Critical Care Medicine and 2 Department of Physiology and Biophysics, University of Washington, Seattle 98195; and 3 Barlow Scientific, Incorporated, and The Evergreen State College, Olympia, Washington 98505
With the use of a newly developed Imaging Cryomicrotome to determine the spatial location of fluorescent microspheres in organs, we validate and report our processing algorithms for measuring regional blood flow in small laboratory animals. Microspheres (15-µm diameter) of four different fluorescent colors and one radioactive label were simultaneously injected into the left ventricle of a pig. The heart and kidneys were dissected, and the numbers of fluorescent and radioactive microspheres were determined in 10 randomly selected pieces. All microsphere counts fell well within the 95% expected confidence limits as determined from the radioactive counts. Fluorescent microspheres (15-µm diameter) of four different colors were also injected into the tail vein of a rat and the left ventricle of a rabbit. After correction for Poisson noise, correlation coefficients between the colors were 0.99 ± 0.02 (means ± SD) for the rabbit heart and 0.99 ± 0.02 for the rat lung. Mathematical dissection algorithms, statistics to analyze the spatial data, and methods to visualize blood flow distributions in small animal organs are presented.
fluorescent microspheres; organ perfusion; spatial distribution; heterogeneity
This article has been cited by other articles:
![]() |
A. Riddle, N. Ling Luo, M. Manese, D. J. Beardsley, L. Green, D. A. Rorvik, K. A. Kelly, C. H. Barlow, J. J. Kelly, A. R. Hohimer, et al. Spatial heterogeneity in oligodendrocyte lineage maturation and not cerebral blood flow predicts fetal ovine periventricular white matter injury. J. Neurosci., March 15, 2006; 26(11): 3045 - 3055. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. J. E. Lamm, S. L. Bernard, W. W. Wagner Jr., and R. W. Glenny Intravital microscopic observations of 15-{micro}m microspheres lodging in the pulmonary microcirculation J Appl Physiol, June 1, 2005; 98(6): 2242 - 2248. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. K. M. Decking, V. M. Pai, E. Bennett, J. L. Taylor, C. D. Fingas, K. Zanger, H. Wen, and R. S. Balaban High-resolution imaging reveals a limit in spatial resolution of blood flow measurements by microspheres Am J Physiol Heart Circ Physiol, September 1, 2004; 287(3): H1132 - H1140. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Matsumoto, H. Tachibana, T. Asano, M. Takemoto, Y. Ogasawara, K. Umetani, and F. Kajiya Pattern differences between distributions of microregional myocardial flows in crystalloid- and blood-perfused rat hearts Am J Physiol Heart Circ Physiol, April 1, 2004; 286(4): H1331 - H1338. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. F Unger Experimental evaluation of coronary collateral development Cardiovasc Res, February 16, 2001; 49(3): 497 - 506. [Abstract] [Full Text] [PDF] |
||||