AJP - Heart Calcium Transients and Cell-Sarcomere
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 271: H1807-H1813, 1996;
0363-6135/96 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pythoud, F.
Right arrow Articles by Meister, J. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pythoud, F.
Right arrow Articles by Meister, J. J.

AJP - Heart and Circulatory Physiology, Vol 271, Issue 5 1807-H1813, Copyright © 1996 by American Physiological Society


ARTICLES

Method for determining distribution of reflection sites in the arterial system

F. Pythoud, N. Stergiopulos, N. Westerhof and J. J. Meister
Biomedical Engineering Laboratory, Swiss Federal Institute of Technology, PSE-Ecublens, Lausanne, Switzerland.

We developed a new method to determine the location and importance of reflection sites in the arterial system. The method is based on the decomposition of the aortic pressure wave into its forward and backward components, and it provides the reflection profile of the arterial system as a wave reflection site amplitude versus distance from the heart. The reflection profile can be seen as the response of the arterial system to a pressure delta pulse where reflections upstream from the measurement location have been eliminated. The method was successfully tested on a simple model loaded with a pure resistor, a two-element windkessel, and a bifurcating tube system. It was then applied to the aortic pressure and flow signals measured in six mongrel dogs whose aorta was occluded at different levels. The profiles obtained from measurements at control showed two main reflection regions, one located in the vicinity (0.1-0.2 m) of the heart and the other located in the region of the iliac bifurcation. All occlusions, even the most distant one at the iliac bifurcation, could be identified in both amplitude (amount of reflections) and distance from the heart. The spatial resolution of the profiles was approximately 0.1 m as a result of the limited power spectrum contained in the arterial pulse, and the identification of reflection sites decreased rapidly with the distance.