AJP - Heart Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 259: H1071-H1078, 1990;
0363-6135/90 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nakajima, T.
Right arrow Articles by Shiga, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nakajima, T.
Right arrow Articles by Shiga, T.

AJP - Heart and Circulatory Physiology, Vol 259, Issue 4 1071-H1078, Copyright © 1990 by American Physiological Society


ARTICLES

Deformation response of red blood cells in oscillatory shear flow

T. Nakajima, K. Kon, N. Maeda, K. Tsunekawa and T. Shiga
Department of Physiology, School of Medicine, Ehime University, Japan.

The characteristics of red cell deformation were studied, focusing on deformation response of the cells subjected to oscillatory shear stress. Red blood cells were fractionated into subpopulations of different densities, i.e., low-density and high-density cells. The deformation response of the fractionated cells was evaluated with a rheoscope varying their intracellular viscosity and oscillation frequency of the applied shear stress, and determinants of the deformation response were compared with those of whole cell deformation under stationary shear stress. When the fractionated cells were exposed to sinusoidally oscillated shear stress, the cells underwent oscillatory deformation. The degree of deformation of the low-density cells correspond to the magnitude of the applied shear stress up to an oscillation frequency of 2.7 Hz. Meanwhile, such an oscillatory deformation as to correspond to the applied shear stress was observed up to 1.7 Hz for the high-density cells. It was suggested that intracellular viscosity was an important factor to determine the deformation response of red cells to oscillatory shear stress.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
G. S. Kassab, E. R. Lontis, A. Horlyck, and H. Gregersen
Novel method for measurement of medium size arterial lumen area with an impedance catheter: in vivo validation
Am J Physiol Heart Circ Physiol, April 1, 2005; 288(4): H2014 - H2020.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online