AJP - Heart Watch the video to learn how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 258: H1457-H1463, 1990;
0363-6135/90 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Canty, J. M.
Right arrow Articles by Brooks, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Canty, J. M., Jr
Right arrow Articles by Brooks, A.

AJP - Heart and Circulatory Physiology, Vol 258, Issue 5 1457-H1463, Copyright © 1990 by American Physiological Society


ARTICLES

Phasic volumetric coronary venous outflow patterns in conscious dogs

J. M. Canty Jr and A. Brooks
Department of Medicine, State University of New York, Buffalo School of Medicine.

We performed the present study to characterize phasic venous outflow patterns in conscious chronically instrumented dogs. An implantable ultrasonic transit-time flow probe capable of measuring volumetric venous outflow was placed on the coronary sinus (n = 9) and/or great cardiac vein (n = 5). Under resting conditions, great cardiac vein flow was predominantly systolic [systolic index 61 +/- 6%/beat (means +/- SD), diastolic index 39 +/- 6%/beat]. In contrast, coronary sinus volumetric flow was predominantly diastolic (systolic index 36 +/- 13%/beat, diastolic index 64 +/- 13%/beat). During adenosine vasodilation both great cardiac vein and coronary sinus flow patterns were predominantly systolic (systolic index 58 +/- 12%/beat for the coronary sinus and systolic index 75 +/- 6%/beat in great cardiac vein flow). In addition, the time at which peak venous flow occurred shifted from end systole to midsystole after vasodilation. The variation in coronary venous flow patterns with position suggests that outflow patterns are significantly influenced by a venous compliance between the great cardiac vein and distal coronary sinus. The lack of a predominantly systolic outflow pattern in the coronary sinus under resting conditions contrasts with previous findings in open-chest anesthetized animals and raises the possibility that cannulation of the coronary sinus and/or changes in vasomotor tone caused by anesthesia alter resting venous flow patterns.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
B. J. Hart, X. Bian, P. A. Gwirtz, S. Setty, and H. F. Downey
Right ventricular oxygen supply/demand balance in exercising dogs
Am J Physiol Heart Circ Physiol, August 1, 2001; 281(2): H823 - H830.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. K. Lund, M. F. Wendland, A. Shimakawa, H. Arheden, F. Ståhlberg, C. B. Higgins, and M. Saeed
Coronary Sinus Flow Measurement by Means of Velocity-encoded Cine MR Imaging: Validation by Using Flow Probes in Dogs
Radiology, November 1, 2000; 217(2): 487 - 493.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online