AJP - Heart Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 257: H1312-H1314, 1989;
0363-6135/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Held-Munzenmaier, D.
Right arrow Articles by Boerboom, L. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Held-Munzenmaier, D.
Right arrow Articles by Boerboom, L. E.

AJP - Heart and Circulatory Physiology, Vol 257, Issue 4 1312-H1314, Copyright © 1989 by American Physiological Society


ARTICLES

A sheath for repetitive insertion of high-fidelity micromanometer-tipped catheters

D. Held-Munzenmaier, G. N. Olinger and L. E. Boerboom
Department of Cardiothoracic Surgery, Medical College of Wisconsin, Milwaukee 53226.

Implantation of micromanometer-tipped catheters into dogs and other animals for invasive high-fidelity blood pressure measurement is expensive and impractical. We have devised an implantable sheath that allows insertion of the transducer each time the animal is to be studied. This eliminates animal-inflicted damage and the need for multiple transducers if several animals are to be instrumented concurrently. The sheath is coextruded from hard and soft forms of polyurethane to form a soft, flexible, thrombus-resistant tubing with a hard thin inner lining having a low coefficient of friction. This allows chronic implantation of the sheath into the heart and major vessels with minimal trauma, yet enables a transducer to be advanced through a sheath only slightly larger than the transducer itself without the frictional resistance common to other soft tubing. The sheath can be tapered for ease of implantation into vessels or curved to the appropriate angle for implantation into the heart. Our polyurethane sheath is a versatile, convenient, and inexpensive alternative to chronic instrumentation with transducers for high-fidelity pressure measurement.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. D. Tune, K. N. Richmond, M. W. Gorman, and E. O. Feigl
KATP+ channels, nitric oxide, and adenosine are not required for local metabolic coronary vasodilation
Am J Physiol Heart Circ Physiol, February 1, 2001; 280(2): H868 - H875.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. W. Gorman, J. D. Tune, K. N. Richmond, and E. O. Feigl
Feedforward sympathetic coronary vasodilation in exercising dogs
J Appl Physiol, November 1, 2000; 89(5): 1892 - 1902.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
K. N. Richmond, J. D. Tune, M. W. Gorman, and E. O. Feigl
Role of KATP+ channels and adenosine in the control of coronary blood flow during exercise
J Appl Physiol, August 1, 2000; 89(2): 529 - 536.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. D. Tune, K. N. Richmond, M. W. Gorman, R. A. Olsson, and E. O. Feigl
Adenosine is not responsible for local metabolic control of coronary blood flow in dogs during exercise
Am J Physiol Heart Circ Physiol, January 1, 2000; 278(1): H74 - H84.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online