AJP - Heart Calcium Transients and Cell-Sarcomere
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 257: H1306-H1311, 1989;
0363-6135/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schmalzel, J. L.
Right arrow Articles by Shepherd, A. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schmalzel, J. L.
Right arrow Articles by Shepherd, A. P.

AJP - Heart and Circulatory Physiology, Vol 257, Issue 4 1306-H1311, Copyright © 1989 by American Physiological Society


ARTICLES

An optical hemoglobinometer for whole blood

J. L. Schmalzel, J. M. Steinke, V. T. Randal and A. P. Shepherd
Department of Physiology, University of Texas Health Science Center, San Antonio 78284.

To overcome the disadvantages of the presently available hemoglobinometers, we have developed an optical instrument that measures the total hemoglobin (Hb) concentration in whole, undiluted blood. The device uses an infrared light-emitting diode to illuminate a capillary tube filled with a sample of whole blood. Light scattered in the blood travels a short distance down the length of the capillary tube, passes through a second light path, and reaches a photodetector, the output of which is amplified, digitized, and fed into a microprocessor. The microprocessor computes the Hb concentration as a nonlinear function of the light intensity. The optical device yielded Hb content measurements that correlated well with standard methods (r = 0.99, slope = 0.94, mean absolute difference = 0.75 g Hb/dl). Thus the accuracy appears to be less than 1 g Hb/dl. The advantages of the present device are as follows: 1) no chemical reaction is required (hence neither accurate dilutions nor toxic reagents are necessary); 2) it reads Hb concentration within a few seconds; 3) it can be operated by unskilled personnel; 4) it could be made portable and thus could be operated in the field, in rural settings, or at accident sites; 5) sample size is small (25-70 microliters); and 6) the same capillary tube can be centrifuged if a measure of hematocrit is also desired. A detailed parts list and circuit diagram are presented, and sources of error are discussed.