AJP - Heart AJP: Advances in Physiology Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 257: H969-H978, 1989;
0363-6135/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Alexander, J.
Right arrow Articles by Sagawa, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Alexander, J., Jr
Right arrow Articles by Sagawa, K.

AJP - Heart and Circulatory Physiology, Vol 257, Issue 3 969-H978, Copyright © 1989 by American Physiological Society


ARTICLES

Influence of mean pressure on aortic impedance and reflections in the systemic arterial system

J. Alexander Jr, D. Burkhoff, J. Schipke and K. Sagawa
Department of Biomedical Engineering, Johns Hopkins Medical School, Baltimore, Maryland 21205.

The present investigation sought to determine the extent to which primary changes in mean arterial pressure (MAP) might influence the calculated aortic impedance. In seven open-chest, anesthetized, autonomically blocked dogs, we measured aortic impedance using white-noise analysis at various levels of MAP achieved by adjusting the height of a left atrial reservoir rather than by pharmacological intervention. Impedance spectra so obtained were parameterized according to best-fit wind-kessel models (Ra, Rc, Ca) and three parameters to characterize wave reflections: the frequency at which the phase of the impedance approached or crossed through 0 degree (phi 0), the frequency of the first minimum of the impedance modulus (fmin), and the amplitude of the first oscillation of the impedance modulus (a 1). The dependency of each of these parameters on MAP was investigated. In addition, we calculated the reflection coefficient spectrum (RCS). Results show that windkessel parameters were not significantly influenced by MAP and that the reflection parameters and the RCS depended on increased levels of MAP in a manner consistent with an increase in pulsewave velocity.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. D. Constable, G. W. Smith, G. E. Rottinghaus, M. E. Tumbleson, and W. M. Haschek
Fumonisin-induced blockade of ceramide synthase in sphingolipid biosynthetic pathway alters aortic input impedance spectrum of pigs
Am J Physiol Heart Circ Physiol, June 1, 2003; 284(6): H2034 - H2044.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
W. J. Stok, R. C. O. Stringer, and J. M. Karemaker
Noninvasive cardiac output measurement in orthostasis: pulse contour analysis compared with acetylene rebreathing
J Appl Physiol, December 1, 1999; 87(6): 2266 - 2273.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C.-H. Chen, E. Nevo, B. Fetics, P. H. Pak, F. C.P. Yin, W. L. Maughan, and D. A. Kass
Estimation of Central Aortic Pressure Waveform by Mathematical Transformation of Radial Tonometry Pressure : Validation of Generalized Transfer Function
Circulation, April 1, 1997; 95(7): 1827 - 1836.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online