AJP - Heart Calcium Transients and Cell-Sarcomere
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 256: H1684-H1689, 1989;
0363-6135/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Campbell, K. B.
Right arrow Articles by Noordergraaf, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Campbell, K. B.
Right arrow Articles by Noordergraaf, A.

AJP - Heart and Circulatory Physiology, Vol 256, Issue 6 1684-H1689, Copyright © 1989 by American Physiological Society


ARTICLES

Pulse reflection sites and effective length of the arterial system

K. B. Campbell, L. C. Lee, H. F. Frasch and A. Noordergraaf
Department of Veterinary and Comparative Anatomy, Washington State University, Pullman 99163.

The concept of effective length (L) of the arterial system implies that it may be represented by a single viscoelastic tube terminated by an impedance, creating a single reflection site. Although the concept is straightforward, investigators for years have been unable to agree on the value of L. Proposed values range from a few millimeters to a few meters, confounding the identification of arterial reflection sites. This report shows analytically and illustrates with experimental data that the determination of the effective length leaves room for an infinite number of exact solutions for L and the corresponding terminal impedance if the input impedance of the tube is to match the measured input impedance of an arterial system. None of the possible values of L needs to bear any relationship to actual reflection sites.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
R. Burattini and K. B. Campbell
Comparative analysis of aortic impedance and wave reflection in ferrets and dogs
Am J Physiol Heart Circ Physiol, January 1, 2002; 282(1): H244 - H255.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. M. Quick, W. L. Young, and A. Noordergraaf
Infinite number of solutions to the hemodynamic inverse problem
Am J Physiol Heart Circ Physiol, April 1, 2001; 280(4): H1472 - H1479.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. M. Quick, D. S. Berger, and A. Noordergraaf
Constructive and destructive addition of forward and reflected arterial pulse waves
Am J Physiol Heart Circ Physiol, April 1, 2001; 280(4): H1519 - H1527.
[Abstract] [Full Text] [PDF]


Home page
HypertensionHome page
D. S. Berger, K. A. Robinson, and S. G. Shroff
Wave Propagation in Coupled Left Ventricle–Arterial System : Implications for Aortic Pressure
Hypertension, May 1, 1996; 27(5): 1079 - 1089.
[Abstract] [Full Text]


Home page
CirculationHome page
W. K. Laskey, W. G. Kussmaul, and A. Noordergraaf
Valvular and Systemic Arterial Hemodynamics in Aortic Valve Stenosis : A Model-Based Approach
Circulation, September 15, 1995; 92(6): 1473 - 1478.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online