AJP - Heart Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 256: H1493-H1499, 1989;
0363-6135/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ferrari, M.
Right arrow Articles by Traystman, R. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ferrari, M.
Right arrow Articles by Traystman, R. J.

AJP - Heart and Circulatory Physiology, Vol 256, Issue 5 1493-H1499, Copyright © 1989 by American Physiological Society


ARTICLES

Noninvasive determination of hemoglobin saturation in dogs by derivative near-infrared spectroscopy

M. Ferrari, D. A. Wilson, D. F. Hanley, J. F. Hartmann, M. C. Rogers and R. J. Traystman
Department of Anesthesiology, Johns Hopkins Medical Institutions, Baltimore, Maryland 21205.

An in vivo method utilizing derivative near-infrared spectroscopy was developed to noninvasively determine cerebral venous hemoglobin O2 saturation (SVO2). The method was tested on eight pentobarbital-anesthetized dogs ventilated with differing inspired O2 mixtures to force changes in SVO2 over a wide range. Spectral data obtained by transilluminating the tissues surrounding the superior sagittal sinus (SS) were transformed into first derivative units for correlation with SVO2 data measured from the SS. Linear regression analysis was applied to data obtained from five dogs and used to build a three-wavelength algorithm for predicting brain SVO2. In three dogs, SVO2 was varied to test this equation ability to predict SVO2. The standard deviation of differences between measured SVO2 and SVO2 predicted from 31 separate spectra was 3.2%. These predicted values, when regressed against the sampled SVO2, yielded an r value of 0.97. The results demonstrate that during hypoxic hypoxia (HH) it is possible to noninvasively quantify SVO2 with the use of infrared spectroscopy.


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
C. D. Kurth, J. M. Steven, S. C. Nicolson, and M. L. Jacobs
CEREBRAL OXYGENATION DURING CARDIOPULMONARY BYPASS IN CHILDREN
J. Thorac. Cardiovasc. Surg., January 1, 1997; 113(1): 71 - 79.