AJP - Heart Calcium Transients and Cell-Sarcomere
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 256: H1087-H1099, 1989;
0363-6135/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Liu, Z. R.
Right arrow Articles by Yin, F. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Liu, Z. R.
Right arrow Articles by Yin, F. C.

AJP - Heart and Circulatory Physiology, Vol 256, Issue 4 1087-H1099, Copyright © 1989 by American Physiological Society


ARTICLES

Impedance of arterial system simulated by viscoelastic t tubes terminated in windkessels

Z. R. Liu, F. Shen and F. C. Yin
Department of Applied Mechanics, Fudan University, Shanghai, China.

An improved asymmetric t-tube model of the arterial system is proposed. The model consists of two viscoelastic tubes of differing lengths, each terminated in a modified windkessel with inductance as well as resistance and compliance. Equations for calculating the input impedance of this model are presented. Using typical data from the literature, the model predicts a more realistic impedance modulus and phase than previous models of the circulation. Parametric analysis shows that when peripheral compliances are altered, sharp peaks in the very low frequency portions of the impedance spectra are produced, whereas alterations of either the characteristic impedances or inductances of the terminations have little effect on input impedance. Alteration of the elasticity or relative lengths of the tubes results in shifts in the positions of the maxima and minima akin to those observed experimentally. Change in the viscosity of the walls or of the blood only affects the fluctuations of the impedance spectra without affecting the positions of the maxima and minima. Thus, with this still simple model, very realistic impedance spectra are obtainable. The model provides more insight than previously proposed models into the individual influence of various parameters of the proximal and peripheral vasculature on central hemodynamics.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
R. Burattini and K. B. Campbell
Comparative analysis of aortic impedance and wave reflection in ferrets and dogs
Am J Physiol Heart Circ Physiol, January 1, 2002; 282(1): H244 - H255.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. M. Quick, W. L. Young, and A. Noordergraaf
Infinite number of solutions to the hemodynamic inverse problem
Am J Physiol Heart Circ Physiol, April 1, 2001; 280(4): H1472 - H1479.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online