AJP - Heart Calcium Transients and Cell-Sarcomere
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 256: H302-H310, 1989;
0363-6135/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hope, I. D.
Right arrow Articles by Longo, L. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hope, I. D.
Right arrow Articles by Longo, L. D.

AJP - Heart and Circulatory Physiology, Vol 256, Issue 1 302-H310, Copyright © 1989 by American Physiological Society


ARTICLES

Errors in microsphere determination of cardiac output: a computer simulation in fetal sheep

I. D. Hope, F. J. Huikeshoven, R. D. Gilbert, G. G. Power and L. D. Longo
Department of Physiology, School of Medicine, Loma Linda University, California 92350.

Through use of a compartmental model, we simulated the measurement of cardiac output and distribution by means of radioactively labeled microspheres in fetal lambs with weights between 0.5 and 3 kg. A systematic error in measured cardiac output caused by artifactual changes in blood volume caused by the injection and withdrawal of fluids during the procedure was less than 5% for fetal weights greater than or equal to 1 kg but increased for fetal weights less than 1 kg and when hypovolemia was simulated at all fetal weights. Sensitivity analysis disclosed no significant effect of changes in vascular resistance. We examined the effects of recirculation of microspheres and found no significant increase in error in the measured value of cardiac output due to 20% recirculation of all spheres entering a single isolated organ system; however, errors between 7 and 14% were observed with simulations of 20% recirculation in more than one compartment simultaneously. Recirculation also introduced significant errors in the measured distribution of cardiac output in certain cases. The effect on the measured cardiac output of a temporary change in the true cardiac output was dampened by the artifactual blood volume changes mentioned above and the fact that the measurement is a time-weighted average. We also evaluated four different experimental designs. We conclude that the microsphere technique provides a remarkably reliable means of quantifying cardiac output and individual organ flow in the fetus. The nonrandom errors inherent in the procedure examined in this study are of the order of 10%, which is likely to be less than the moment-to-moment variation in the true cardiac output.