AJP - Heart AJP: Renal Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 253: H1335-H1341, 1987;
0363-6135/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smith, T. L.
Right arrow Articles by Murphy, W. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smith, T. L.
Right arrow Articles by Murphy, W. R.

AJP - Heart and Circulatory Physiology, Vol 253, Issue 6 1335-H1341, Copyright © 1987 by American Physiological Society


ARTICLES

Hemodynamic monitoring for 24 h in unanesthetized rats

T. L. Smith, T. G. Coleman, K. A. Stanek and W. R. Murphy
Department of Physiology and Pharmacology, Bowman Gray School of Medicine of Wake Forest University, Winston-Salem, North Carolina 27103.

A new technique is described that allows minute-to-minute recordings of cardiac output and arterial pressure in unanesthetized rats for periods of 24 h and longer. Rats were instrumented with electromagnetic flow probes and arterial catheters. An electrical and hydraulic swivel was interposed between the rat and recording apparatus to allow free range of movement. Data were collected and analyzed once each minute by computer. Average 24-h values (mean +/- SD) for the following hemodynamic variables were determined in eight rats [expressed where appropriate as a function of body weight (BW)]: cardiac output (98.1 +/- 14.7 ml/min), cardiac index (29.2 +/- 4.4 ml.min-1.100 g BW-1), mean arterial pressure (92.5 +/- 7.8 mmHg), heart rate (347 +/- 45 beats/min), peak aortic flow (403 +/- 32 ml/min), stroke volume (282 +/- 26 microliters), stroke volume index (84.4 +/- 8.1 microliters/100 g BW), and total peripheral resistance index (3.26 +/- 0.46 mmHg.ml-1.min.100 g BW). These results provide a data base of hemodynamic values for unanesthetized adult, Sprague-Dawley male rats, which has not been previously available. In addition, cardiac index, mean arterial pressure, and total peripheral resistance index demonstrated diurnal variation. Diurnal variation contributed substantially to the overall variance observed within these variables. Hourly variance was also substantial and indicates the use of continuous recordings for short-term experiments.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online