AJP - Heart Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 252: H851-H856, 1987;
0363-6135/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Geffin, G. A.
Right arrow Articles by Daggett, W. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Geffin, G. A.
Right arrow Articles by Daggett, W. M.

AJP - Heart and Circulatory Physiology, Vol 252, Issue 4 851-H856, Copyright © 1987 by American Physiological Society


ARTICLES

Microsphere reference flow samples during systemic flow adjustment

G. A. Geffin, D. D. O'Keefe, A. G. Denenberg and W. M. Daggett

Regional myocardial blood flow measurements in the right heart bypass preparation can be particularly valuable, since this preparation provides control of the main hemodynamic determinants of coronary blood flow. We examined the validity of aortic reference flow samples in relation to coronary samples during continuous systemic flow adjustment for aortic pressure control in six dogs on right heart bypass, anesthetized with chloralose and urethan. Microsphere concentrations were compared in paired reference flow samples drawn from the aortic arch and from a coronary artery for 119 left atrial microsphere injections. During left subclavian artery infusion and during femoral artery infusion at rates above 2,000 ml/min, there were high percentage errors in microsphere concentration between paired samples, consistent with aortic sample dilution by systemically infused blood. In 52 injections during withdrawal or femoral infusion below 2,000 ml/min, at cardiac outputs of 390-4,800 ml/min, the percentage error was 0.001 +/- 1.18% (SE); the absolute value of this error was below 20% in 96%, and below 10% in 77% of these injections. Linear regression related these coronary to aortic microsphere concentrations by the equation Y = 1.005X - 1.64, r = 0.997, Sy.x = 13.2 (5.9%). (Sy.x represents the standard deviation from regression.) These data indicate that valid aortic reference flow samples can be obtained within specific hemodynamic conditions during systemic flow adjustment in the right heart bypass preparation.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
D. F. Torchiana, A. J. Vine, J. S. Titus, C. Hahn, K. O. Shebani, G. A. Geffin, and W. M. Daggett
The temperature dependence of cardioplegic distribution in the canine heart
Ann. Thorac. Surg., August 1, 2000; 70(2): 614 - 620.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online