AJP - Heart Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 248: H477-H484, 1985;
0363-6135/85 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sunagawa, K.
Right arrow Articles by Sagawa, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sunagawa, K.
Right arrow Articles by Sagawa, K.

AJP - Heart and Circulatory Physiology, Vol 248, Issue 4 477-H484, Copyright © 1985 by American Physiological Society


ARTICLES

Stroke volume effect of changing arterial input impedance over selected frequency ranges

K. Sunagawa, W. L. Maughan and K. Sagawa

We investigated the effect of changing arterial input impedance over three selected frequency ranges on stroke volume (SV) in nine isolated canine left ventricles. The input impedance was simulated with a three-element Windkessel model (i.e., resistance, characteristic impedance, and compliance) and was imposed on the ventricles with a servo-controlled loading system. Under a constant end-diastolic volume [33.1 +/- 1.5 (SE) ml], we changed the modulus of the afterloaded impedance over a low frequency range (below 0.13 Hz) by changing the resistance, over a transitional frequency range (in which the impedance modulus decreases from total resistance to characteristic impedance) by changing the compliance, and over a high frequency range (above 2.0 Hz) by changing the characteristic impedance. Each of the impedance components was changed from control to 50 and 200% of control. SV sensitively decreased from 16.1 +/- 0.7 to 7.4 +/- 0.5 ml in response to the increase in the low-frequency impedance modulus. SV was relatively insensitive, however, to the same percent increase in the impedance modulus over the transitional frequency range (from 11.2 +/- 0.6 to 12.3 +/- 0.7 ml) and over the high frequency range (from 11.9 +/- 0.6 to 11.6 +/- 0.7 ml). The average relative sensitivities of SV to the increase and decrease in impedance moduli in these frequency ranges were 1.2:0.12:0.04. We conclude that the modulus of impedance in the low frequency range is, by far, a more important determinant of SV than those in the transitional and high frequency ranges.


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Morita, T. Asou, I. Kuboyama, Y. Harasawa, K. Sunagawa, and H. Yasui
Inelastic vascular prosthesis for proximal aorta increases pulsatile arterial load and causes left ventricular hypertrophy in dogs
J. Thorac. Cardiovasc. Surg., October 1, 2002; 124(4): 768 - 774.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
S. G. Lage, L. Kopel, C. C. J. Medeiros, R. T. Carvalho, and M. A. Creager
Angiotensin II contributes to arterial compliance in congestive heart failure
Am J Physiol Heart Circ Physiol, October 1, 2002; 283(4): H1424 - H1429.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
P. Kolh, V. D'Orio, B. Lambermont, P. Gerard, C. Gommes, and R. Limet
Increased aortic compliance maintains left ventricular performance at lower energetic cost
Eur. J. Cardiothorac. Surg., March 1, 2000; 17(3): 272 - 278.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online