AJP - Heart Watch the video to learn how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 242: H154-H160, 1982;
0363-6135/82 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Piene, H.
Right arrow Articles by Sund, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Piene, H.
Right arrow Articles by Sund, T.

AJP - Heart and Circulatory Physiology, Vol 242, Issue 2 154-H160, Copyright © 1982 by American Physiological Society


ARTICLES

Does normal pulmonary impedance constitute the optimum load for the right ventricle?

H. Piene and T. Sund

Right ventricular performance of isolated supported cat hearts was experimentally characterized by a relationship among ventricular pressure (P), volume (V), and time after onset of systole. This characterization was combined with a hypothetical load network consisting of lumped central and peripheral lung vascular resistances (Rc and Rp), inertance (L), and compliance (C). We calculated ventricular and load pressure, flow, external ventricular work (Wext), static ventricular P-V energy (Wstat), and pump efficiency Q = Wext/Wstat over a broad range of load conditions. Magnitudes of load network variables resulting in a maximum value of Q would define the load impedance matching the ventricle. A practical optimum magnitude of lumped vascular compliance was obtained at C = 150 x 10(-6) g-1 . cm4, above which no substantial change in Q took place. We obtained maximum Q at approximately 4 ml stroke volume (heart rate = 2 Hz) and at characteristic impedance between 0.75 and 1.1 x 10(3)g . cm-1 . s-1. As these values are quite close to those encountered in the intact animal, we conclude that the right ventricular and the pulmonary arterial tree appear to constitute a matched pump-load system.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J.-W. Lankhaar, N. Westerhof, T. J. C. Faes, K. M. J. Marques, J. T. Marcus, P. E. Postmus, and A. Vonk-Noordegraaf
Quantification of right ventricular afterload in patients with and without pulmonary hypertension
Am J Physiol Heart Circ Physiol, October 1, 2006; 291(4): H1731 - H1737.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online